CAMDEN, NJ —
OSHA Inspection: CAMDEN IRON AND METAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAMDEN IRON AND METAL, INC. in 1500 S 6TH STREET, CAMDEN, NJ 08104 (NAICS 423930). OSHA activity number 340445337.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAMDEN IRON AND METAL, INC.
- Site address
- 1500 S 6TH STREET
- City
- CAMDEN
- State
- NJ
- ZIP
- 08104
- Mailing
- 143 HARDING AVENUE, BELLMAWR, NJ 08031
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 40
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.110 F02 I
- Issued
- Jul 28, 2015
- Penalty
- Initial $2,100 · Current $1,155 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): LP-Gas Containers were not stored in a manner to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons: a) Camden Iron and Metal - Outside Maintenance Department/work shop: LP gas containers were located in the immediate area of forklifts, the cylinders were not secured to minimized accidental physical damage, observed on or about 03/03/2015.
Recent events (2)
- — I (S) $1155
- — Z (S) $2100
1910.253 B02 II
- Issued
- Jul 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Camden Iron and Metal Inc. - Outside maintenance area: Acetylene compressed gas cylinders were not secured from being knocked over, observed on or about 03/03/2015. b) Camden Iron and Metal Inc. - Maintenance shop: Liquefied Petroleum gas cylinders were not secured from being knocked over, observed on or about 03/03/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 I09
- Issued
- Jul 28, 2015
- Penalty
- Initial $3,500 · Current $1,925 Reduced
General-duty citation text
29 CFR 1910.184(i)(9): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present. a) Camden Iron and Metal Inc. - Maintenance shop: A sling used to lift equipment parts was damaged and was not removed from service. Observed on or about 03/03/2015.
Recent events (2)
- — I (S) $1925
- — Z (S) $3500
1910.212 B
- Issued
- Jul 28, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Camden Iron and Metal Inc. - Maintenance area: Top heavy machinery such as the Dayton 13" drill press Model # 75Z1463, S/N 810208 was not bolted to the floor, observed on or about 03/03/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.215 A01
- Issued
- Jul 28, 2015
- Abate by
- Aug 21, 2015
- Penalty
- Initial $2,100 · Current $1,155 Reduced
General-duty citation text
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s): a) Camden Iron and Metal Inc. - Maintenance department: Employees used an unguarded Dayton 8" Bench Grinder S/N 4Z909D, observed on or about 03/03/2015.
Recent events (2)
- — I (S) $1155
- — Z (S) $2100
1910.244 A01 II
- Issued
- Jul 28, 2015
- Abate by
- Aug 21, 2015
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.244(a)(1)(ii): Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means: a)Camden Iron and Metal Inc. - Maintenance department: The portable jacks used to service multiple equipment and vehicles were no marked with the rated load, Observed on or about 03/03/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.334 A02 II
- Issued
- Jul 28, 2015
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) Camden Iron and Metal Inc. - Maintenance shop area: A welder machine had damaged casing on the welding cables. The welding machine was used by employees on a regular basis., observed on or about 03/03/2015.
Recent events (2)
- — I (S) $1540
- — Z (S) $2800
1910.303 G01 II
- Issued
- Jul 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Camden Iron and Metal Inc. - Maintenace shop: An electrical panel was blocked by material next to the staircase. Observed on or about 03/03/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jul 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Camden Iron and Metal Inc. - Maintenance department: An electrical panel powering equipment in the facility had missing knock out on the side of the panel, observed on or about 03/03/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C04
- Issued
- Jul 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: a) Camden Iron and Metal Inc. - Maintenance department: A Fire extinguisher located in the third level of the maintenance department was discharge, that area is use for storage, observed on or about 03/03/2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Camden Iron and Metal, INC.
View Camden Iron and Metal, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340445337.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.