OSHA Inspection: MCVAY DRILLING CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCVAY DRILLING CO. in RIG 1, 51 MILES NE OF KENT, KENT, TX 79855 (NAICS 213111). OSHA activity number 340445550.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcvay Drilling CO. — free Get an email when a new federal OSHA severe-injury report for Mcvay Drilling CO. is published. One employer, no account, unsubscribe in one click.
Establishment
MCVAY DRILLING CO.
Site address
RIG 1, 51 MILES NE OF KENT
City
KENT
State
TX
ZIP
79855
Mailing
401 EAST BENDER, HOBBS, NM 88241
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
16
Ownership type
A

4 citations on file for this inspection.

1910.23 A07

Other-than-serious 1 instance 2 exposed
Issued
Mar 30, 2015
Abate by
Apr 3, 2015
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.23(a)(7): Every temporary floor opening did not have standard railings, or was not constantly attended by someone:    On or about March 3, 2015, McVay Rig #1, at the top of the suction pits, three 28-inches x 28-inches floor openings were left unguarded exposing employees to fall hazards greater than 4-feet.
Recent events (2)
  • — I (O) $2295
  • — Z (S) $2295

1910.23 A08

Other-than-serious 1 instance 2 exposed
Issued
Mar 30, 2015
Abate by
Apr 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:    On or about March 3, 2015, McVay Rig #1, at the top of the suction pits, three 12-inches x 12-inches floor holes were left unguarded exposing employees to trip hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.304 G05

Other-than-serious 1 instance 6 exposed
Issued
Mar 30, 2015
Abate by
Apr 3, 2015
Penalty
Initial $3,825 · Current $2,000 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about March 3, 2015, at McVay Rig #1, the engine room was not grounded, an electrode rod used for the propose of grounding was inserted into the ground with ground wires attached but was not connected to the structure(s). The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $3825

1910.305 J03 I

Other-than-serious 1 instance 1 exposed
Issued
Mar 30, 2015
Abate by
Apr 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(3)(i): Appliances had live parts normally exposed to employee contact:    On or about March 3, 2015, at McVay Rig #1, in the upper left corner of the mud house, the bottom cover of the 480V Q-Mark Heater (Model No. MUH 154) was un-attached from the rest of the unit exposing live wiring and employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0