OSHA Inspection: GARDEN STREET IRON & METAL INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GARDEN STREET IRON & METAL INC. in 3350 METRO PARKWAY, NORTH FORT MYERS, FL 33916 (NAICS 423930). OSHA activity number 340446442.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garden Street Iron & Metal INC. — free Get an email when a new federal OSHA severe-injury report for Garden Street Iron & Metal INC. is published. One employer, no account, unsubscribe in one click.
Site address
3350 METRO PARKWAY
City
NORTH FORT MYERS
State
FL
ZIP
33916
Mailing
3350 METRO PARKWAY, NORTH FORT MYERS, FL 33916
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
68
Ownership type
A

8 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $2,618 · Current $1,571 Reduced
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:  a. At the warehouse receiving area, the safety guard on the DoAll Band Saw was adjusted in the full upward position, exposing employees to a amputation hazard, on or about 3/4/2015.
Recent events (2)
  • — I (S) $1570.8
  • — Z (S) $2618

1910.243 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $2,618 · Current $1,571 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):  a. In the shredder building's maintenance shed, a Makita Hand Held Grinder (Model 9557PB) was used with the safety guard removed, exposing an employee to a struck-by hazard, on or about 3/4/2015.
Recent events (2)
  • — I (S) $1570.8
  • — Z (S) $2618

1910.212 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
May 11, 2015
Penalty
Initial $6,160 · Current $3,696 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:   a. In the receiving area warehouse, the alligator shear was missing the safety guard, exposing employees to a amputation hazard, on or about 3/4/2015.   Garden Street Iron & Metal, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 316106285, citation number 1, item number 3 and was affirmed as a final order on 3/14/2012, with respect to a workplace located at 3350 Metro Pkwy, Fort Myers, FL.
Recent events (2)
  • — I (R) $3696
  • — Z (R) $6160

1910.303 G02 I

Other-than-serious 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   a. In the receiving area warehouse, the cover for the power control box on the alligator shear was broken, exposing the electrical connections inside the control box, on or about 3/4/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 E01

Other-than-serious 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in wet locations were not weatherproof:  a. On the pin puller mezzanine deck, the electrical outlet was missing the weatherproof cover, exposing employees to an electrical hazard, on or about 3/4/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a. In the receiving area warehouse, portable extension cords were secured to the frame of the warehouse and were used to provide power to a portable fan, refrigerator, and microwave oven over extended periods of time, exposing employees to a electrical hazard, on or about 3/4/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   a. On the pin puller mezzanine deck, the flexible power cord for the pin puller had the outer sheath pulled thus transmitting pull on the terminal connections, exposing employees to an electrical hazard, on or about 3/4/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06

Other-than-serious 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:    a. In the tire maintenance building, secondary containers holding motor oil and antifreeze were not labeled, exposing employees to a chemical hazard, on or about 3/4/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0