On , OSHA opened a referral safety inspection of TIMBER TECHNOLOGIES, LLC in 106 BREMER AVENUE, COLFAX, WI 54730 (NAICS 321213). OSHA activity number 340448190.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Timber Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Timber Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
106 BREMER AVENUE
City
COLFAX
State
WI
ZIP
54730
Mailing
106 BREMER AVENUE, COLFAX, WI 54730
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321213
Employees
17
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II C

Serious Gravity 1 1 instance 10 exposed
Issued
Mar 24, 2015
Abate by
May 12, 2015
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.   (a) Throughout the facility; The energy control procedure did not identify means for removing or transferring lockout devices or tagout devices.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.147 C06 II

Serious Gravity 1 1 instance 10 exposed
Issued
Mar 24, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:   (a) Throughout the facility; The employer did not certify that periodic inspections of energy isolation procedures were conducted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 24, 2015
Abate by
Apr 7, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) Finger jointing table; The flexible cord on a portable circular saw was not inspected for damage. The outer jacket and insulation were damaged in several locations.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600