Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: H. SHOEMAKER WELDING AND MACHINE SHOP, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of H. SHOEMAKER WELDING AND MACHINE SHOP, INC. in 302 LEIDY ROAD, SOUDERTON, PA 18964 (NAICS 332710). OSHA activity number 340450451.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch H. Shoemaker Welding and Machine Shop, INC. — free Get an email when a new federal OSHA severe-injury report for H. Shoemaker Welding and Machine Shop, INC. is published. One employer, no account, unsubscribe in one click.
Site address
302 LEIDY ROAD
City
SOUDERTON
State
PA
ZIP
18964
Mailing
302 LEIDY ROAD, SOUDERTON, PA 18964
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
24
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 3 instances 5 exposed
Issued
Apr 9, 2015
Abate by
May 5, 2015
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  a)  Fabrication Shop - On or about March 11, 2015, the employer did not develop specific hazardous energy control procedures for the Accurpress 175T Press Brake (Model #717512).  b)  Fabrication Shop - On or about March 11, 2015, the employer did not develop specific hazardous energy control procedures for the Wysong 90T Press Brake (Model #H-90-6).  a)  Fabrication Shop - On or about March 11, 2015, the employer did not develop specific hazardous energy control procedures for the Strippit Mechanical 30T Punch Press (Model Super 30-30).
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.147 C07 I

Serious Gravity 5 3 instances 4 exposed
Issued
Apr 9, 2015
Abate by
May 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) Throughout Facility - On or about March 11, 2015, employees who perform servicing and maintenance, to include set up such as die changes, were not trained to the level required for authorized employees in employees were not trained in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  b)  Throughout Facility - On or about March 11, 2015, employees who operate equipment on which servicing and maintenance are performed, were not trained to the level for affected employees, in that each affected employee was not instructed in the purpose and use of the energy control procedures.  c)  Throughout Facility - On or about March 11, 2015, all other employees whose work operations are or may be in an area where energy control procedures may be utilized, were instructed about the procedure, and about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked out or tagged out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 9, 2015
Abate by
Jun 14, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a)  Weld Shop - On or about March 11, 2015, employees operating the Accurpress 175T Press Brake were not protected from having their hands in the danger zone during operation.     (b)  Weld Shop - On or about March 11, 2015, employees operating the Wysong 90T Press Brake were not protected from having their hands in the danger zone during operation.     (c)  Weld Stock Shop - On or about March 11, 2015, no less than two points of operation of the Geka Hdracrop 55/SD Ironworker were not guarded in that the guards were missing on the discharge side of the Flat Shear and Angle Cutter.    Abatement Note:  Two reference documents which provide methods for safeguarding power press brakes are:   1.  ANSI B11.3-1982, Safety Requirements for Power Press Brakes, Section 6.1.4  2.  OSHA CPL 02-01-025, Guidelines for Point of Operation Guarding of Power Press Brakes
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340450451.