Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELMET TECHNOLOGIES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELMET TECHNOLOGIES, LLC in 1560 LISBON STREET, LEWISTON, ME 04240 (NAICS 331491). OSHA activity number 340451327.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elmet Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Elmet Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1560 LISBON STREET
City
LEWISTON
State
ME
ZIP
04240
Mailing
1560 LISBON STREET, LEWISTON, ME 04240
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331491
Employees
180
Ownership type
A

13 citations on file for this inspection.

1910.178 Q07

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 15, 2015
Abate by
Apr 21, 2015
Penalty
Initial $2,295 · Current $1,492 Reduced
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift:  Shipping Department - The examination of the Yale forklift for defects was inadequate in that the brake lights and strobe light were not functional.
Recent events (2)
  • — I (S) $1491.75
  • — Z (S) $2295

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2015
Penalty
Initial $3,825 · Current $2,486 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Maintenance Shop - The rotating blade on the Do-All vertical bandsaw was inadequately guarded.
Recent events (2)
  • — I (S) $2486.25
  • — Z (S) $3825

1910.215 A04

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 15, 2015
Abate by
Apr 22, 2015
Penalty
Initial $3,825 · Current $2,475 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:     In the following instances, work rests were not properly adjusted to one-eighth inch:    a) Treating Room -The Wissoter E-7W bench grinder work rest was placed below the abrasive wheel housing.    b) Fire Wire Drawing Room - The Wolfe Industries bench grinder was work rest adjusted to one-quarter inch.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $3825

1910.215 B09

Serious Gravity 5 3 instances 3 exposed
Issued
Apr 15, 2015
Abate by
Apr 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  In the following instances, the tongue guard was not properly adjusted to one fourth inch:  a) Treating Room - The Wissoter E-7W bench grinder did not have a tongue guard.  b) Fine Wire Drawing Room - The Wolfe Industries bench grinder tongue guard was adjusted one-half inch from the abrasive wheel.  c) Phase 1 Machine Shop - Bench Grinder Asset #22342H did not have a tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 5 instances 3 exposed
Issued
Apr 15, 2015
Abate by
May 4, 2015
Penalty
Initial $3,825 · Current $2,486 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  In the following instances, horizontal shafts inadequately or not guarded:  a) Sheer Department - The sheer's guard for the rotating shaft was inadequate in that 1/2 inch of the shaft was exposed.  b) Swaging Area - The swaging station had guards for the rotating shaft were inadequate in that ~1 inch of the shaft was exposed.
Recent events (2)
  • — I (S) $2486.25
  • — Z (S) $3825

1910.242 B

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 15, 2015
Abate by
Apr 27, 2015
Penalty
Initial $3,825 · Current $2,486 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  Surface Grinding Areas - The compressed air used by the operator for cleaning purposes on the surface grinder was measured at 90 p.s.i with no means to reduce the pressure to less than 30 p.s.i.
Recent events (2)
  • — I (S) $2486.25
  • — Z (S) $3825

1910.303 F02

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 15, 2015
Penalty
Initial $3,825 · Current $2,486 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Fabrication Shop - Circuits 26 & 28 in a 120/208 volt electrical panel LP-35 were not labeled for their purpose.
Recent events (2)
  • — I (S) $2486.25
  • — Z (S) $3825

1910.303 G01 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2015
Penalty
Initial $3,825 · Current $2,486 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:   Maintenance Shop - The Cut-off Saw was situated approximately 29 inches from the Westinghouse 120/208 volt 3 phase electrical panel.
Recent events (2)
  • — I (S) $2486.25
  • — Z (S) $3825

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2015
Penalty
Initial $3,825 · Current $2,486 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   East Cafeteria - The money changing machine was missing a grounding pin.
Recent events (2)
  • — I (S) $2486.25
  • — Z (S) $3825

1910.305 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 15, 2015
Penalty
Initial $2,295 · Current $1,492 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  In the following instances, flexible cords did not have strain relief:  a) 2 Hi Mill Area - The flexible cord used to recharge the Swift electric pallet jack.  b) Fabrication Shop - The yellow extension cord energizing the right angle drill.
Recent events (2)
  • — I (S) $1491.75
  • — Z (S) $2295

1910.37 B01

Other-than-serious 2 instances 2 exposed
Issued
Apr 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1):  Each exit was not adequately lighted so that an employee with normal vision can see along the exit route:  In the following instances, the battery operated exit lights did not work:  a) First floor, main office hallway   b) East cafeteria
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.144 A01 III

Other-than-serious 6 instances 6 exposed
Issued
Apr 15, 2015
Abate by
Apr 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.144(a)(1)(iii): Emergency stop bars, stop buttons or switches which letters or other markings appear, used for emergency stopping of machinery were not red:  Heavy Wire Drawing Area - The emergency stop buttons' labeling on the heavy wire drawing equipment had faded to where it was difficult to immediately recognize.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 4 exposed
Issued
Apr 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  East Cafeteria - The Frigidaire refrigerator was energized by an extension cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Elmet Technologies, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340451327.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.