POMPANO BEACH, FL —
OSHA Inspection: CLINT KITCHEN & BATH INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CLINT KITCHEN & BATH INC. in 1000 SOUTH DIXIE HIGHWAY BAY A028-027, POMPANO BEACH, FL 33060 (NAICS 337110). OSHA activity number 340451731.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLINT KITCHEN & BATH INC.
- Site address
- 1000 SOUTH DIXIE HIGHWAY BAY A028-027
- City
- POMPANO BEACH
- State
- FL
- ZIP
- 33060
- Mailing
- 811 SW 63RD TERRACE, NORTH LAUDERDALE, FL 33068
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.213 A10
- Issued
- May 19, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(a)(10): It is recommended that each power-driven woodworking machine be provided with a disconnect switch that can be locked in the off position: (a): On or about April 16, 2015, employees were exposed to electrical hazards when using a Delta 10 Inch Left Tilt Contractor's Table Saw that did not have a magnetic cut-off switch preventing the saw from automatically starting in the event of a power failure.
Recent events (3)
- — J (S) $0
- — C (S) $2000
- — Z (S) $2000
1910.213 C01
- Issued
- May 19, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a): On or about April 16, 2015, at the above addressed worksite, employees were exposed to amputation hazards while using an unguarded Delta 10 Inch Left Tilt Contractor's Table Saw.
Recent events (3)
- — J (S) $0
- — C (S) $2000
- — Z (S) $2000
1910.303 B02
- Issued
- May 19, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a): On or about April 16, 2015, at the above addressed worksite, employees were exposed to electrical hazards while using a Delta 10 Inch Left Tilt Contractor's Table Saw that had a flush mount type electrical enclosure for the on/off switch.
Recent events (3)
- — J (S) $0
- — C (S) $1600
- — Z (S) $1600
1910.305 B01 II
- Issued
- May 19, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a): On or about April 16, 2015, at the above addressed worksite, employees were exposed to electrical hazards while using a Delta 10 Inch Left Tilt Contractor's Table Saw that had a flush mount type electrical enclosure for the on/off switch that was missing knockouts.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- May 19, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: (a): On or about April 16, 2015, at the above addressed worksite, employees were exposed to electrical hazards while using a Makita portable hand held router with a spliced cord.
Recent events (3)
- — J (S) $0
- — C (S) $1600
- — Z (S) $1600
1910.305 G02 III
- Issued
- May 19, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a): On or about April 16, 2015, at the above addressed worksite, employees were exposed to electrical hazards while using a Craftsman Air Compressor that was missing a strain relief.