Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: K & B CONSTRUCTION AND REMODELING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of K & B CONSTRUCTION AND REMODELING, INC. in 770 GAGE LN., LAKE FOREST, IL 60045 (NAICS 238130). OSHA activity number 340456540.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch K & B Construction and Remodeling, INC. — free Get an email when a new federal OSHA severe-injury report for K & B Construction and Remodeling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
770 GAGE LN.
City
LAKE FOREST
State
IL
ZIP
60045
Mailing
8208 N. NEW ENGLAND AVE., NILES, IL 60714
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 16, 2015
Abate by
Jul 20, 2015
Penalty
Initial $2,000 · Current $960 Reduced
29 CFR 1926.602(d): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178:        29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):       a) The employer did not train and evaluate employees operating the Terex SS6440 all terrain forklift.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $960
  • — Z (S) $2000

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 16, 2015
Penalty
Initial $2,800 · Current $960 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      a)  Employees engaged in carpentry work were not protected from fall hazards while working at an elevation of approximately 14 feet above the ground.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $960
  • — Z (S) $2800

1926.1052 C01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 16, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1052(c)(1)(i):  Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge:       a)  Employees were exposed to the hazard of falling while using a stairway that was not equipped with a stairrail system.       No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.404 B01 II

Other-than-serious 1 instance 4 exposed
Issued
Jun 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii):  Where an assured equipment grounding program was not utilized, receptacles were not protected with ground fault circuit interrupters when on a two-wire, single- phase portable or vehicle-mounted generator rated more than 5kW, or where the circuit conductors of the generator were not insulated from the generator frame and all other grounded surfaces:    a)  Employees were using three-wire 120/240 Volt, Champion Power Equipment, Model #71530, with receptacle not protected with ground fault circuit interrupters to power tools onsite.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.404 F06

Other-than-serious 1 instance 4 exposed
Issued
Jun 16, 2015
Abate by
Jun 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:   a)  Extension cords, used by employees during carpentry work, did not have permanent and continuous path to ground.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View K & B Construction and Remodeling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340456540.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.