POOLER, GA —
OSHA Inspection: FRANCISCO MARIN
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of FRANCISCO MARIN in 128 WAVERLY LANE LOT # 129, POOLER, GA 31322 (NAICS 238130). OSHA activity number 340456821.
Where did this inspection happen?
- Establishment
- FRANCISCO MARIN
- Site address
- 128 WAVERLY LANE LOT # 129
- City
- POOLER
- State
- GA
- ZIP
- 31322
- Mailing
- 9902 FERGUSON AVE LOT#101, SAVANNAH, GA 31406
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Mar 24, 2015
- Abate by
- Apr 17, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) Pooler construction site, on or about, and at times preceding to March 9, 2015, employees working on ground and lower levels who were exposed to being struck-by wooden boards, equipment, and nails were not protected by the use of hard hats.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.102 A01
- Issued
- Mar 24, 2015
- Abate by
- Apr 17, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) Pooler construction site, on or about, and at times preceding to March 9, 2015, employees utilizing pneumatic nail guns and a circular saw were not wearing eye protection.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.405 G02 IV
- Issued
- Mar 24, 2015
- Abate by
- Apr 17, 2015
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) Pooler Construction Site, on or about March 9, 2015, flexible extension cord used for powering the Makita circular saw was missing strain relief on the female end.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.416 E01
- Issued
- Mar 24, 2015
- Abate by
- Apr 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) Pooler Construction Site, on or about March 9, 2015, flexible extension cord used for powering the Makita circular saw had damaged sheathing near the female end.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Mar 24, 2015
- Abate by
- Apr 17, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Pooler construction site, on or about, and times preceding to March 9, 2015, employees subject to a 9.8-foot fall hazard while framing a house were not provided with fall protection.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1053 B01
- Issued
- Mar 24, 2015
- Abate by
- Apr 17, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Pooler Construction site, on or about March 9, 2015, aluminum ladder to gain access to 9.8 foot roof level for framing operations, was extended one foot beyond roof line.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340456821.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.