OSHA Inspection: STEIL OIL COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STEIL OIL COMPANY, INC. in 1031 U.S. 1, VERO BEACH, FL 32960 (NAICS 447110). OSHA activity number 340457829.

Watch Steil OIL Company, INC. — free Get an email when a new federal OSHA severe-injury report for Steil OIL Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1031 U.S. 1
City
VERO BEACH
State
FL
ZIP
32960
Mailing
1033 MIRICLE MILE, VERO BEACH, FL 32960
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
447110
Employees
2
Ownership type
A

4 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  On or about March 11, 2015 at the above addressed jobsite, employees were dispensing LP gas with no eye protection, exposing the employees to a fire hazard.
Recent events (1)
  • — Z (S) $0

1910.138 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances, severe cuts or lacerations, severe abrasions, punctures, chemical burns, thermal burns, and harmful temperature extremes.  On or about March 11, 2015 at the above addressed jobsite, employees were dispensing LP gas with no hand protection, exposing the employees to a fire hazard.
Recent events (1)
  • — Z (S) $0

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.39(a)(2): Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, the employer did not report the in-patient hospitalization, amputation, or loss of an eye to OSHA.  On or about March 9, 2015, the employer reported a hospitalization for an accident that had occurred on March 2, 2015.
Recent events (1)
  • — Z (O) $0

1910.157 C04

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(4): The employer did not assure that portable fire extinguishers were maintained in a fully charged and operable condition and kept in their designated places at all times except during use:  On or about March 11, 2015, at the above addressed jobsite, a fire extinguisher located at the LP gas dispensing unit was not fully charged, exposing the employees to a fire hazard.
Recent events (1)
  • — Z (O) $0

AK, INC

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340457829.