Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TVM MECHANICAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TVM MECHANICAL in 155 EAST 79TH STREET, NEW YORK, NY 10075 (NAICS 238220). OSHA activity number 340459452.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TVM Mechanical — free Get an email when a new federal OSHA severe-injury report for TVM Mechanical is published. One employer, no account, unsubscribe in one click.
Establishment
TVM MECHANICAL
Site address
155 EAST 79TH STREET
City
NEW YORK
State
NY
ZIP
10075
Mailing
162 JEAN AVE, SOUTH HEMPSTEAD, NY 11550
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 16, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.  On or about March 12, 2015  Location 155 East 79th Street, New York, NY 11th floor, Northeast Corner  (a) Employee was sweating the joint on 3/4" copper domestic water riser pipes and was exposed to sever eye injuries because he was not wearing suitable eye and face protection to prevent burns from the use of a plumbers MAP GAS torch, and 50-50 Tin-Lead solder.
Recent events (1)
  • — Z (S) $2000

1926.403 I02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.  On or About March 12, 2015  LOCATION; 155 East 79th Street, New York, NY 8th Floor By Stairway A  A) Employees working on the 8th floor were exposed to energized parts in an unguarded circuit breaker panel.
Recent events (1)
  • — Z (S) $2000

1926.502 I04

Serious Gravity 5 4 instances 2 exposed
Issued
Apr 16, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:  On or About March 12, 2015  Location:  155 East 79th Street, New York, NY,  11th, 10th, 8th, and 6th floors  a). Employees were exposed to fall hazards in excess of 10' to the surface below because the floor holes adjacent to the coolant shafts were not covered with covers bearing the words "HOLE" or "COVER"
Recent events (1)
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340459452.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.