MYERSTOWN, PA —
OSHA Inspection: OWL CREEK CONSTRUCTION, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OWL CREEK CONSTRUCTION, LLC in 2091 CAMP SWATARA RD, MYERSTOWN, PA 17067 (NAICS 238160). OSHA activity number 340465731.
Where did this inspection happen?
- Establishment
- OWL CREEK CONSTRUCTION, LLC
- Site address
- 2091 CAMP SWATARA RD
- City
- MYERSTOWN
- State
- PA
- ZIP
- 17067
- Mailing
- 2091 CAMP SWATARA RD, MYERSTOWN, PA 17067
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 9
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.453 B02 V
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) T-4-31 - Employees installing a metal roof were exposed to a fall hazard of approximately seventeen (17) feet from an aerial lift without the use of at least a body belt and lanyard , on or about March 16th, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) T-4-19 - Employees installing metal roofing on an approximate 3X12 pitch roof were exposed to a fall hazard of approximately six (6) foot six (6) inches while not protected by the use of a guardrail system, safety net system or a personal fall arrest system, on or about March 16th, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.501 B11
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toe-boards, safety net systems, or personal fall arrest systems: a) T-4-31 - Employees installing metal roofing on a 5 X 12 pitch roof were exposed to an approximate seventeen (17) foot fall without the use of a guardrail system, safety net system, or personal fall arrest systems, on or about March 16th, 2015. b) T-4-19 - Employees installing metal roofing on a 6 X 12 pitch roof were exposed to an approximate nine (9) to seventeen (17) foot fall without the use of a guardrail system, safety net system, or personal fall arrest systems, on or about March 16th, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1440.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) T-4-19 - Employees accessing and egressing from the roof were exposed to a fall hazard of nine (9) feet from the edge of the roof while using an eight (8) foot step ladder, on or about March 16th, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1926.1053 B06
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1440.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not level: a) T-4-19 - Employees working on the end cap of a metal roof were exposed to a nine (9) foot fall hazard from using an eight (8) foot step ladder on two surfaces of different height to access and egress from the roof, on or about March 16th, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) T-4-19 - Employees working on the end cap of a metal roof were exposed to a nine (9) foot fall hazard from using an eight (8) foot out of service step ladder to access and egress from the roof, on or about March 16th, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340465731.