MEYERSDALE, PA —
OSHA Inspection: ITI TRUCK AND TRAILER BODIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ITI TRUCK AND TRAILER BODIES, INC. in 8535 MASON DIXON HIGHWAY, MEYERSDALE, PA 15552 (NAICS 336111). OSHA activity number 340467570.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ITI TRUCK AND TRAILER BODIES, INC.
- Site address
- 8535 MASON DIXON HIGHWAY
- City
- MEYERSDALE
- State
- PA
- ZIP
- 15552
- Mailing
- 8535 MASON DIXON HIGHWAY, MEYERSDALE, PA 15552
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336111
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 B02
- Issued
- Jun 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Facility, Miller Welder A: On or before March 16, 2015, a welder's power cord was connected with a retention device designed for electrical cable. b) Facility, Miller Welder B: On or before March 16, 2015, a welder's power cord was connected with a retention device designed for electrical cable. c) Facility, Miller Welder C: On or before March 16, 2015, a welder's power cord was connected with a retention device designed for electrical cable.
Recent events (1)
- — Z (O) $0
1910.303 B07 IV
- Issued
- Jun 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) Facility, Miller Welder A: On or before March 16, 2015, a welder's power cord had its outer insulation cut and taped. b) Facility, Miller Welder B: On or before March 16, 2015, a welder's power cord had its outer insulation cut and taped. c) Facility, Miller Welder C: On or before March 16, 2015, a welder's power cord had its outer insulation cut and taped.
Recent events (1)
- — Z (O) $0
1910.179 F06 III
- Issued
- Jun 16, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(f)(6)(iii): All floor, remote and pulpit operated crane bridge drives were not provided with a brake or non-coasting mechanical drive: (a) Facility, Crane Number 4: On or before March 16, 2014, a crane used to transport components for truck and trailer body manufacturing was operating without brakes on its bridge.
Recent events (1)