ILION, NY ·
OSHA Inspection: ORIGINAL HERKIMER COUNTY CHEESE CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ORIGINAL HERKIMER COUNTY CHEESE CO., INC. in 2745 STATE ROUTE 51 SOUTH, ILION, NY 13357 (NAICS 311513). OSHA activity number 340470681.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ORIGINAL HERKIMER COUNTY CHEESE CO., INC.
- Site address
- 2745 STATE ROUTE 51 SOUTH
- City
- ILION
- State
- NY
- ZIP
- 13357
- Mailing
- 2745 STATE ROUTE 51 SOUTH, ILION, NY 13357
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311513
- Employees
- 25
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.37 A03
- Issued
- Apr 1, 2015
- Abate by
- Apr 9, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Smoke Room, on or about 3/17/15: Exit door was blocked by snow. Abatement certification must be submitted for this item.
Recent events (2)
- · I (S) $714
- · Z (S) $1020
1910.37 A04
- Issued
- Apr 1, 2015
- Abate by
- May 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) Dipping Cooler, on or about 3/17/15: Exit light was not working. b) Gel Room, on or about 3/17/15: Exit light was not working. c) Shipping Hall, on or about 3/17/15: Three exit lights were not working. d) Loading Dock area, on or about 3/17/15: Three exit lights were not working. Abatement certification must be submitted for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.157 G02
- Issued
- Apr 1, 2015
- Abate by
- May 6, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) At the establishment, on or about 3/17/15: Annual training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting. *ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy as outlined in 29 CFR 1910.38 and 29 CFR 1910.39 which includes the evacuation requirements of 29 CFR 1910.157(b). Abatement certification must be submitted for this item.
Recent events (2)
- · I (S) $714
- · Z (S) $1020
1910.212 A01
- Issued
- Apr 1, 2015
- Abate by
- May 6, 2015
- Penalty
- Initial $1,700 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Diecut Room, on or about 3/17/15: Ingoing nip points and point of operation were not adequately guarded on a cheese grinder. Abatement certification must be submitted for this item.
Recent events (2)
- · I (S) $1190
- · Z (S) $1700
1910.305 G01 IV A
- Issued
- Apr 1, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Assembly Area, on or about 3/17/15: An extension cord providing current to a Better Pack tape machine was strung along the floor along the conveyor line and being used as permanent wiring. Abatement certification must be submitted for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Original Herkimer County Cheese CO., INC.
View Original Herkimer County Cheese CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311513)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340470681.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.