OSHA Inspection: COMMUNITY ECONOMIC DEVELOPMENT ASSOCIATION OF COOK COUNTY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of COMMUNITY ECONOMIC DEVELOPMENT ASSOCIATION OF COOK COUNTY in 3518 W. 139TH ST., ROBBINS, IL 60472 (NAICS 624229). OSHA activity number 340473750.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Community Economic Development Association of Cook County — free Get an email when a new federal OSHA severe-injury report for Community Economic Development Association of Cook County is published. One employer, no account, unsubscribe in one click.
Site address
3518 W. 139TH ST.
City
ROBBINS
State
IL
ZIP
60472
Mailing
3518 W. 139TH ST., ROBBINS, IL 60472
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
624229
Employees
40
Ownership type
A

5 citations on file for this inspection.

1910.36 A03

Serious Gravity 1 2 instances 20 exposed
Issued
May 1, 2015
Abate by
Jun 18, 2015
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.36(a)(3): Openings into an exit must be limited. An exit is permitted to have only those openings necessary to allow access to the exit from occupied areas of the workplace, or to the exit discharge. An opening into an exit must be protected by a self-closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a nationally recognized testing laboratory. Section 1910.155(c)(3)(iv)(A) of this part defines "listed" and �� 1910.7 of this part defines a "nationally recognized testing laboratory."   a. Third Floor/Eastside of building - On or about March 24, 2015, the exit route's door did not have a self-closing mechanism and a sounding fire alarm system. Employees were thereby exposed to fire hazards.  b. Third Floor/Westside of Building - On or about March 24, 2015, the exit route's door did not have a self-closing mechanism and a sounding fire alarm system. Employees were thereby exposed to fire hazards.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

1910.37 A03

Serious Gravity 1 2 instances 20 exposed
Issued
May 1, 2015
Abate by
Jun 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.  a. Third Floor/Eastside of the Building - On or about March 24, 2015, a metal railing/door with a lock was placed within the exit route. Employees were thereby exposed to fire hazards.  b. Third Floor/Westside of the Building - On or about March 24, 2015, a metal railing/door with a lock was placed within the exit route. Employees were thereby exposed to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.38 B

Other-than-serious 1 instance 20 exposed
Issued
May 1, 2015
Abate by
Jun 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.38(b): Written and oral emergency action plans. An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees.  a. Three Floor Building - On or about March 24, 2015, the employer did not have a written emergency action plan for employees. Employees were thereby exposed to fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 A04 I

Other-than-serious 1 instance 20 exposed
Issued
May 1, 2015
Abate by
May 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(4)(i): Any receptacle used for putrescible solid or liquid waste or refuse shall be so constructed that it does not leak and may be thoroughly cleaned and maintained in a sanitary condition. Such a receptacle shall be equipped with a solid tight-fitting cover, unless it can be maintained in a sanitary condition without a cover. This requirement does not prohibit the use of receptacles which are designed to permit the maintenance of a sanitary condition without regard to the aforementioned requirements.  a. Third Floor/Women's washroom - On or about March 24, 2015, the garbage container did not have a tight - fitting cover/lid. Employees were thereby exposed to unsanitary conditions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 D01

Other-than-serious 1 instance 10 exposed
Issued
May 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(1): General. Requirements - Washing facilities shall be maintained in a sanitary condition.  a. Third Floor - Women's washroom - On or about March 24, 2015, the left side stall was not provided with toilet paper tissue. Employees were thereby exposed to unsanitary conditions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340473750.