Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAC TRAILER SERVICE INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MAC TRAILER SERVICE INC. in 14504 COMMERCE STREET, ALLIANCE, OH 44601 (NAICS 811118). OSHA activity number 340473958.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MAC Trailer Service INC. — free Get an email when a new federal OSHA severe-injury report for MAC Trailer Service INC. is published. One employer, no account, unsubscribe in one click.
Site address
14504 COMMERCE STREET
City
ALLIANCE
State
OH
ZIP
44601
Mailing
14504 COMMERCE STREET, ALLIANCE, OH 44601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811118
Employees
62
Ownership type
A

12 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 6, 2015
Abate by
Aug 26, 2015
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:     Respirators with chemical cartridges were used by employees on a voluntary basis during tanker and hopper entry and during some welding done on truck trailers.  No program was implemented to determine if employees were medically able to use the respirator.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.146 D04 I

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.146(d)(4)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide, at no cost to the employees, testing and monitoring equipment needed to comply with 29 CFR 1910.146(d)(5):     Employees enter  tankers and hopper trailers which were used to carry gasoline or other chemicals, to do cleaning, inspections and repairs.  No testing equipment capable of testing  for residual levels of chemicals that could be contained in the confined space was provided.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.146 F01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.146(f)(1): The entry permit that documented compliance and authorized entry to a permit space did not identify the permit space to be entered:    Permits issued for entry to tanks or hopper trailer covered entries made on 3/6/15, 7/1/15, 7/6/15 and 7/9/15 did not identify the confined space.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.146 F02

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(f)(2): The entry permit that documented compliance and authorized entry to a permit space did not identify the purpose of the entry:    Permits issued for entry to tanks or hopper trailer covered entries made on 3/6/15, 7/1/15, 7/6/15 and 7/9/15 did not identify the purpose of the entry.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 F07

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(f)(7): The entry permit that documented compliance and authorized entry to a permit space did not identify the hazards of the permit space to be entered:    Permits issued for entry to tanks or hopper trailer covered entries made on 3/6/15, 7/1/15, 7/6/15 and 7/9/15 did not identify the hazards of the entry. This should include, but is not limited to,  the chemicals that had been carried in the tanker or hopper trailer and the physical configuration which could limit access to the space.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G01

Serious Gravity 1 1 instance 62 exposed
Issued
Aug 6, 2015
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    On or about 3/18/15, employees had not been trained in the use of fire extinguishers.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.1026 D01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Nov 10, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):       No air sampling was done to determine employee exposure during welding work on stainless steel.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.1026 L01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.1026(l)(1)(i): 29 CFR 1910.1026(l)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication standard, 29 CFR 1910.1200:     No information or training was provided for employees who weld on stainless steel trailer parts.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.1026 L02 I

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(l)(2)(i): Prior to initial job assignment to an area where employees were subject to hexavalent chromium exposure, the employer did not ensure that each employee could demonstrate knowledge in the contents of 29 CFR 1910.1026, and the purpose and description of the medical surveillance program required by paragraph (k) of the standard:  No information or training on the standard was provided for employees who weld on stainless steel trailer parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 L02 II

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(l)(2)(ii): The employer did not make a copy of the Chromium (VI) standard, 29 CFR 1910.1026, readily available to all employees who were exposed to chromium (VI):  No copy of the standard was available for employees who weld on stainless steel trailer parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about 3/18/15, no written hazard communication program was maintained on the site for employees who were exposed to welding fume which contains hazardous chemicals including, but not limited to, hexavalent chromium, zinc, copper, manganese and nickel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 II

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 6, 2015
Abate by
Sep 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:  No training was done on the specific health hazards of metal fumes to which employees were exposed during welding.  Welding fume  contains hazardous chemicals including, but not limited to, hexavalent chromium, zinc, copper, manganese and nickel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View MAC Trailer Service INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340473958.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.