BOLINGBROOK, IL —
OSHA Inspection: ILLINOIS INDUSTRIAL TOOL, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ILLINOIS INDUSTRIAL TOOL, INC. in 530B W. FRONTAGE ROAD, BOLINGBROOK, IL 60440 (NAICS 423710). OSHA activity number 340475334.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ILLINOIS INDUSTRIAL TOOL, INC.
- Site address
- 530B W. FRONTAGE ROAD
- City
- BOLINGBROOK
- State
- IL
- ZIP
- 60440
- Mailing
- 530B W. FRONTAGE ROAD, BOLINGBROOK, IL 60440
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423710
- Employees
- 55
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 L01 I
- Issued
- Jul 17, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Warehouse - On or about March 19, 2015, the employer did not ensure that all employees allowed to operate the Crown sit downs and Crown order pickers were trained and evaluated in accordance with paragraph (l), thereby exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.178 Q07
- Issued
- Jul 17, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. Warehouse - On and about March 19, 2015. The employees were required to operate powered industrial vehicles (PIV's). The employer did not ensure that the PIV's were examined before they were placed into service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.176 B
- Issued
- Jul 17, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.176(b): Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse. Warehouse - On or about March 19, 2015, following storage racks were not properly maintained to prevent collapsing, in that up rights, stress bars and cross members were damaged, thereby exposing employees to the hazards associated with unstable stored materials. 1. Rack - North AM -56 upright/ bent cross beam 2. Rack - West BG 26 upright 3. Rack - North AU 01-1 stress bar & cross beam 4. Rack -North ECF-01 stress bar 5. Rack - Northeast NO - 25A & 26 uprights
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.303 G02 I
- Issued
- Jul 17, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: Warehouse northeast wall - On or about March 19, 2015, the cable on the battery charger was defective in that the wires were frayed. Employees were thereby exposed to electrical shock.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
More inspections in this industry (NAICS 423710)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340475334.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.