Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUBLIME RESTORATION COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUBLIME RESTORATION COMPANY in 5915 BLVD EAST, WEST NEW YORK, NJ 07093 (NAICS 238140). OSHA activity number 340477694.

Watch Sublime Restoration Company — free Get an email when a new federal OSHA severe-injury report for Sublime Restoration Company is published. One employer, no account, unsubscribe in one click.
Site address
5915 BLVD EAST
City
WEST NEW YORK
State
NJ
ZIP
07093
Mailing
357 89TH STREET 1ST FLOOR, BROOKLYN, NY 11209
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.  a. 59 boulevard east West New York, NJ.  Employee was observed working from a two-point suspension scaffold that was in close proximity to an energized service drop, thereby exposing the employee to possible electrocution.     Violation occurred on or about 03/16/2015
Recent events (1)
  • — Z (S) $2800

1926.451 G03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(3)(i): When vertical lifelines are used, they shall be fastened to a fixed safe point of anchorage, shall be independent of the scaffold, and shall be protected from sharp edges and abrasion. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights.  a. 59 boulevard east West New York, NJ.  The vertical lifeline for this scaffold were not fastened to a safe point of anchorage as the line was wrapped around an outrigger beam which is not a suitable anchorage point.  Violation occurred on or about 03/16/2015
Recent events (1)
  • — Z (S) $2800

1926.451 H02 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(h)(2)(ii): A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 x 1 1/2 inch (2 x 4 cm) wood or equivalent may be used in lieu of toeboards.   a. 59 boulevard east West New York, NJ.  Workers engaged in masonry activities on the ground below were exposed to falling building materials located at the edge the of the scaffold plank due to missing scaffold toeboards.   Violation occurred on or about 03/16/2015
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340477694.