ELKHORN, NE ·
OSHA Inspection: MANUEL CRUZ VALENZUELA
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of MANUEL CRUZ VALENZUELA in INTERSECTION OF CUMBERLAND ROAD AND 205TH STREET, ELKHORN, NE 68022 (NAICS 238140). OSHA activity number 340482082.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUEL CRUZ VALENZUELA
- Site address
- INTERSECTION OF CUMBERLAND ROAD AND 205TH STREET
- City
- ELKHORN
- State
- NE
- ZIP
- 68022
- Mailing
- 4917 S. 42ND STREET, OMAHA, NE 68107
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Sep 8, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): Worksite located at the intersection of Cumberland Road and 205th Streets, Elkhorn, NE: The working level of a scaffold was not fully planked which decreases the working area for the employees. They were exposed to falls of over 12 feet. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (1)
- · Z (S) $2800
1926.451 C02
- Issued
- Sep 8, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: Worksite located at the intersection of Cumberland Road and 205th Streets, Elkhorn, NE: A fabricated frame scaffold located at the site did not have base plates installed at each lower frame location. This increases the potential for shifting of the scaffold while in use and possible collapse. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (1)
- · Z (S) $2800
1926.451 E01
- Issued
- Sep 8, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Worksite located at the intersection of Cumberland Road and 205th Streets, Elkhorn, NE: The fabricated frame scaffold observed at the job site was not constructed with an acceptable scaffold access method that meets the requirements listed above. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (1)
- · Z (S) $2800
1926.451 F03
- Issued
- Sep 8, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Worksite located at the intersection of Cumberland Road and 205th Streets, Elkhorn, NE: The fabricated frame scaffold observed at the job site had multiple defects (lack of guardrails, incomplete decking, missing base plates, and a bent cross brace) that should have been detected through inspections conducted prior to each work shift. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (1)
- · Z (S) $2800
1926.451 G04 I
- Issued
- Sep 8, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: Worksite located at the intersection of Cumberland Road and 205th Streets, Elkhorn, NE: The employer failed to ensure that guardrails were installed on a fabricated frame scaffold. The employees were exposed to falls of greater than 12 feet while working. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (1)
- · Z (S) $2800
1926.454 A
- Issued
- Sep 8, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Worksite located at the intersection of Cumberland Road and 205th Streets, Elkhorn, NE as well as throughout the company: Employees working a fabricated frame scaffold had not received training as required by the standard. This training should include but is not limited to the hazards associated with the type of scaffold being used. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (1)
- · Z (S) $2800
More inspections in this industry (NAICS 238140)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340482082.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.