JORDAN, NY —
OSHA Inspection: OMEGA WIRE, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of OMEGA WIRE, INC. in 24 NORTH BEAVER STREET, JORDAN, NY 13080 (NAICS 331421). OSHA activity number 340483320.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OMEGA WIRE, INC.
- Site address
- 24 NORTH BEAVER STREET
- City
- JORDAN
- State
- NY
- ZIP
- 13080
- Mailing
- PO BOX 131, CAMDEN, NY 13316
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331421
- Employees
- 64
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.146 K01 II
- Issued
- Apr 13, 2015
- Penalty
- Initial $3,400 · Current $2,210 Reduced
General-duty citation text
29 CFR 1910.146(k)(1)(ii): When designating rescue and emergency services pursuant to paragraph (d)(9), the employer did not evaluate the prospective rescuer's ability, in terms of proficiency with rescue-related tasks and equipment, to function appropriately while rescuing entrants from the particular space or types of spaces identified: a) 114/15 Quench Tank, on or about 11/26/14: The employer did not evaluate the local volunteer fire department's ability to provide rescue services for an emergency involving entry into the 114/15 Quench tank, a permit required confined space.
Recent events (2)
- — I (S) $2210
- — Z (S) $3400
1910.146 K02 IV
- Issued
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(k)(2)(iv): 29 CFR 1910.146(k)(2)(iv): An employer whose employees have been designated to provide permit space rescue and emergency services did not ensure that affected employees practiced making permit space rescues at least once every 12 months: a) 114/15 Quench Tank, on or about 11/26/14: Employees entering 114/15 quench tank, a permit required confined space, were not provided with annual rescue drills.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 K03 II
- Issued
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(k)(3)(ii): An authorized entrant entered a permit space and did not have the other end of the retrieval line attached to a mechanical device or fixed point outside the permit space in such a manner that rescue could begin as soon as the rescuer became aware that a rescue was necessary: a) 114/15 Quench Tank on or about 11/26/14: Neither a mechanical device nor a fixed point was attached to the harnesses of employees entering 114/15 quench tank, a permit required confined space.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Apr 13, 2015
- Abate by
- May 16, 2015
- Penalty
- Initial $3,400 · Current $2,210 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Throughout the facility, on or about 3/23/15: Protection of maintenance employees was not ensures by performing annual review of energy control procedures for machines including, but not limited to, Double Twist Horizontal Bunching machines, SAMP 14 Wire machine with Annealer; 8 Wire machines and 16 Wire machines. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2210
- — Z (S) $3400
1910.1200 E01 I
- Issued
- Apr 13, 2015
- Abate by
- May 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet: a) Throughout the facility, on or about 3/23/15: The list of hazardous chemicals contained in the hazard communication program did not include Sprayon General Purpose Cleaner, RA-400 and Wirol 5000.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G01
- Issued
- Apr 13, 2015
- Abate by
- May 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use a) Throughout the facility, on or about 3/23/15: Safety Data Sheets were not available for Sprayon General Purpose Cleaner, RA-400 and Wirol 5000.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Omega Wire, INC.
View Omega Wire, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331421)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340483320.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.