BRONX, NY —
OSHA Inspection: BRONXWOOD HOME FOR THE AGED
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BRONXWOOD HOME FOR THE AGED in 799 EAST GUN HILL RD., BRONX, NY 10467 (NAICS 623312). OSHA activity number 340486729.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRONXWOOD HOME FOR THE AGED
- Site address
- 799 EAST GUN HILL RD.
- City
- BRONX
- State
- NY
- ZIP
- 10467
- Mailing
- 799 EAST GUN HILL RD., BRONX, NY 10467
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623312
- Employees
- 100
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.132 A
- Issued
- Apr 14, 2015
- Abate by
- Apr 22, 2015
- Penalty
- Initial $2,800 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers was not provided, used, and/or maintained. (a) Laundry room: The employer did not provide chemical-resistant goggles and gloves for employees who are required to use Ammonium Hydroxide when washing laundry at the residence; on or about 03/24/15.
Recent events (2)
- — I (S) $1800
- — Z (S) $2800
1910.141 A03 II
- Issued
- Apr 14, 2015
- Abate by
- May 17, 2015
- Penalty
- Initial $2,800 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.141(a)(3)(ii): Where wet processes were used, drainage was not maintained and false floors, platforms, mats, or other dry standing places were not provided, where practicable, or waterproof footgear was not provided: a) Laundry room: Laundry room drainage was not maintained: on or about 03/26/15. b) Men's locker room: Locker room floors were flooded; on or about 03/26/15.
Recent events (2)
- — I (S) $1800
- — Z (S) $2800
1910.303 B01 VIII
- Issued
- Apr 14, 2015
- Abate by
- Apr 24, 2015
- Penalty
- Initial $4,900 · Current $2,980 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(viii): Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment was not determined using the following considerations: Other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment. a) In basement near men's locker room: The floor dryer was used in a wet/damp area without being connected to a ground fault circuit interrupter (GFCI); on or about 03/25/15.
Recent events (2)
- — I (S) $2980
- — Z (S) $4900
1910.304 G05
- Issued
- Apr 14, 2015
- Abate by
- Apr 24, 2015
- Penalty
- Initial $4,900 · Current $2,980 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective: a) In basement by men's locker room: The electric cord for the floor dryer had a missing ground pin; on or about 03/25/15.
Recent events (2)
- — I (S) $2980
- — Z (S) $4900
1910.305 G01 IV B
- Issued
- Apr 14, 2015
- Abate by
- Apr 24, 2015
- Penalty
- Initial $3,500 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): 29 CFR 1910.305(g)(1)(iv)B: Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors. a) Laundry room: An electrical extension cord ran through a hole in the ceiling to reach a receptacle on the other side of the room to provide power to a "Quick Press" label maker; on or about 03/24/15.
Recent events (2)
- — I (S) $2500
- — Z (S) $3500
1910.1200 E01
- Issued
- Apr 14, 2015
- Abate by
- May 8, 2015
- Penalty
- Initial $2,100 · Current $2,500
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) At facility: Employees use hazardous materials such as but not limited to Ammonium Hydroxide; on or about 03/24/15.
Recent events (2)
- — I (S) $2500
- — Z (S) $2100
1910.1200 H01
- Issued
- Apr 14, 2015
- Abate by
- May 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) At facility: The employees use hazardous materials such as but not limited to Ammonium Hydroxide; on or about 03/24/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1020 G01 I
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1020(g)(1)(i): Upon first entering into employment, and/or at least annually thereafter, the employer did not inform current employees of the existence, location, and availability of any records covered by 29 CFR 1910.1020: a) At facility: The employer had available exposure records such as but not limited to safety data sheets (SDS) for Ammonium Hydroxide; on or about 03/24/15.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1020 G01 II
- Issued
- Apr 14, 2015
- Abate by
- May 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1020(g)(1)(ii): The employer did not inform current employees upon their first entering into employment and at least annually thereafter, of the person responsible for maintaining and providing access to records covered by 29 CFR 1910.1020: a) At facility: The employer had available exposure records such as but not limited to safety data sheets (SDS) for Ammonium Hydroxide; on or about 03/24/15.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1020 G01 III
- Issued
- Apr 14, 2015
- Abate by
- May 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1020(g)(1)(iii): Employees were not informed upon first entering into employment and/or at least annually thereafter of their right to access their medical and/or exposure records: a) At facility: The employer had available exposure records such as but not limited to safety data sheets (SDS) for Ammonium Hydroxide; on or about 03/24/15.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1020 G02
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1020(g)(2): The employer did not keep a copy of 29 CFR 1910.1020 and its appendices at the workplace, and/or, upon request, make copies readily available to employees: a) At facility, 625 Marble Ave Thornwood, NY 10594. The employer had available exposure records such as but not limited to safety data sheets for Ammonium Hydroxide; on or about 03/24/15.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1904.1 A02
- Issued
- Apr 14, 2015
- Abate by
- Apr 22, 2015
- Penalty
- Initial $700 · Current $0 Reduced
General-duty citation text
29 CFR 1904.1(a)(2): The employer did not maintain OSHA injury and illness records. a) At facility: The employer did not maintain the OSHA injury and illness records; on or about 03/24/15.
Recent events (2)
- — I (O) $0
- — Z (O) $700
1904.32 A04
- Issued
- Apr 14, 2015
- Abate by
- Apr 22, 2015
- Penalty
- Initial $700 · Current $0 Reduced
General-duty citation text
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30. a) At facility: The employer did not post the OSHA 300A form for 2014 between February 1 and April 30, 2015; on or about 03/24/15.
Recent events (2)
- — I (O) $0
- — Z (O) $700
More inspections at Bronxwood Home for the Aged
View Bronxwood Home for the Aged's full OSHA safety record →
More inspections in this industry (NAICS 623312)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340486729.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.