EL PASO, TX —
OSHA Inspection: VINO NUEVO EL PASO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VINO NUEVO EL PASO in 988 KESSLER, EL PASO, TX 79907 (NAICS 813110). OSHA activity number 340486794.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VINO NUEVO EL PASO
- Site address
- 988 KESSLER
- City
- EL PASO
- State
- TX
- ZIP
- 79907
- Mailing
- 988 KESSLER, EL PASO, TX 79907
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 813110
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.21 B02
- Issued
- Apr 24, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $3,500 · Current $1,000 Reduced
8870
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about March 24, 2015 the employer did not ensure that employee(s) were trained/instructed in hazard recognition and avoidance of unsafe conditions. These conditions exposed employees to fall hazards and hazards associated with electrical shock.
Recent events (2)
- — I (S) $1000
- — Z (S) $3500
1926.451 F03
- Issued
- Apr 24, 2015
- Abate by
- May 13, 2015
- Penalty
- Initial $0 · Current $0
8870
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about March 24, 2015 the employer did not ensure that scissor lift(s) were inspected and removed when not in safe operable condition. Scissor lifts were missing railing and/or gates, railing on lifts were held with baling wire, operator control panels were not legible, the electrical components and wiring were spliced and/or exposed. These conditions exposed employees to fall hazards and hazards associated with electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Apr 24, 2015
- Abate by
- May 6, 2015
- Penalty
- Initial $3,500 · Current $1,000 Reduced
8870
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about March 24, 2015 the employer did not ensure that an extension cord, powering a miter saw, was equipped with a ground prong. b) On or about March 24, 2015 the employer did not ensure that a miter saw's cord was equipped with a ground prong. c) On or about March 24, 2015 the employer did not ensure that a JLG scissor lift's cord was equipped with a ground prong. This condition exposed employees to hazards associated with electrical shock.
Recent events (2)
- — I (S) $1000
- — Z (S) $3500
1926.405 G02 III
- Issued
- Apr 24, 2015
- Abate by
- May 6, 2015
- Penalty
- Initial $0 · Current $0
8870
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) On or about March 24, 2015 the employer did not ensure that a flexible cord was used in continuous length without a splice. The spliced cord was connected to an air compressor on a Genie lift. b) On or about March 24, 2015 the employer did not ensure that a flexible cord attached to a miter compound saw was used in continuous length without a splice. This condition exposed employees to hazards associated with electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 813110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340486794.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.