Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HEIDELBERG GROUP INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HEIDELBERG GROUP INC. in 3056 STATE ROUTE 28 NORTH, HERKIMER, NY 13350 (NAICS 311812). OSHA activity number 340489780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Heidelberg Group INC. — free Get an email when a new federal OSHA severe-injury report for Heidelberg Group INC. is published. One employer, no account, unsubscribe in one click.
Site address
3056 STATE ROUTE 28 NORTH
City
HERKIMER
State
NY
ZIP
13350
Mailing
P.O. BOX 787, HERKIMER, NY 13350
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
52
Ownership type
A

3 citations on file for this inspection.

1910.37 A04

Other-than-serious 2 instances 10 exposed
Issued
May 13, 2015
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:    a) On or about 3/24/2015, On the Bake Floor:  An exit sign equipped with light bulbs and an emergency light were not operational.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2380

1910.303 F02

Serious Gravity 5 3 instances 10 exposed
Issued
May 13, 2015
Penalty
Initial $2,975 · Current $1,934 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a) On or about 3/24/2015, On the Bake Floor:  Two knife switches and one circuit breaker were not labeled as to what they energized.
Recent events (2)
  • — I (S) $1933.75
  • — Z (S) $2975

1910.303 G01

Serious Gravity 5 3 instances 10 exposed
Issued
May 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   a) On or about 3/24/2015, On the Bake Floor:  Two knife switches and one circuit breaker were blocked by two pallets of baking supplies.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Heidelberg Group INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340489780.