MILTON, NH —
OSHA Inspection: EASTERN BOATS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EASTERN BOATS, INC. in 11 INDUSTRIAL WAY, MILTON, NH 03851 (NAICS 336612). OSHA activity number 340492800.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EASTERN BOATS, INC.
- Site address
- 11 INDUSTRIAL WAY
- City
- MILTON
- State
- NH
- ZIP
- 03851
- Mailing
- 11 INDUSTRIAL WAY, MILTON, NH 03851
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 40
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.134 E01
- Issued
- Apr 15, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Assembly building - On or about March 26, 2015, a medical evaluation was not performed on the employees assigned to wear the 3M respirators.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.184 E01
- Issued
- Apr 15, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Sling identification. Alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and reach. a. Rigging building - On or about March 26, 2015, the steel chain sling in use was not provided with a tag identifying the manufacturer or the sling capability.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.213 P04
- Issued
- Apr 15, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: a. Rigging building - On or about March 26, 2015, the Dayton (model 6Y001) belt and disc sander was not guarded at the pulley's inrunning nip point.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.213 R04
- Issued
- Apr 15, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation of the wood working machines: a. Rigging building - On or about March 26, 2015, the Craftsman 1 1/2 hp router was not provided with a bit guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A04
- Issued
- Apr 15, 2015
- Abate by
- Apr 21, 2015
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. Rigging building - On or about March 26, 2015, the gray bench grinder tool rest was adjusted 2 inches away from the grinding wheel surface.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.335 A01 I
- Issued
- Apr 15, 2015
- Abate by
- Apr 21, 2015
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: Instance a. Site - On or about March 26, 2015, employees performing diagnostic work where live parts were exposed were not protected from burns to the hands/fingers from arc blasts or arc flashes where insulated gloves were not worn. Instance b. Site - On or about March 26, 2015, employees performing diagnostic work where live parts were exposed were not protected from burns to the body from arc blasts or arc flashes where electrical rated clothing were not worn.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.335 A01 V
- Issued
- Apr 15, 2015
- Abate by
- Apr 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes or face: a. Site - On or about January 26, 2015, employees performing diagnostic work where live parts were exposed were not protected from burns to the face and eyes from arc blasts or arc flashes where face shields were not worn.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 A04
- Issued
- Apr 15, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a. Site - On or about March 26, 2015, prior written approval was not obtained for the yellow forklift attachment which was in use on the Hyster 40 forklift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Apr 15, 2015
- Abate by
- Apr 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a. Rigging building - On or about March 26, 2015, the electrical disconnect panel for the Kaeser air compressor was blocked by trash and debris and not made available for emergency or maintenance procedures.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Apr 15, 2015
- Abate by
- Apr 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. Assembly building - On or about March 26, 2015, the electrical receptacle in use to power the Ryobi 10 inch table saw was missing its cover plate.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Eastern Boats, INC.
View Eastern Boats, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340492800.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.