NEW WAVERLY, TX —
OSHA Inspection: CRAIG GODWIN INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CRAIG GODWIN INC. in 9353 STATE HIGHWAY 75, NEW WAVERLY, TX 77358 (NAICS 333999). OSHA activity number 340492842.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRAIG GODWIN INC.
- Site address
- 9353 STATE HIGHWAY 75
- City
- NEW WAVERLY
- State
- TX
- ZIP
- 77358
- Mailing
- P. O. BOX 525, NEW WAVERLY, TX 77358
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 120
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Jun 3, 2015
- Abate by
- Jun 22, 2015
- Penalty
- Initial $6,300 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, was not guarded: The employer does not ensure that the unused portion of the point of operation of a horizontal bandsaw is guarded. This violation was observed on or about March 26, 2015 in the saw department, where an employee was exposed to struck-by and caught-in hazards when operating a HydMech band saw where the unused portion of the blade was not guarded. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure the unused portions of the band saw blade are guarded.
Recent events (2)
- — I (S) $3780
- — Z (S) $6300
1910.304 F01 IV
- Issued
- Jun 3, 2015
- Abate by
- Jun 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: The employer does not keep overcurrent devices readily accessible. This violation was observed on or about March 26, 2015, on the northern wall of the Quality Control Building where employees are expected to access electrical panels that are being blocked by stair step ladders and various rejected equipment parts Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all overcurrent devices are readily accessible were blocking free and clear access of electrical panels.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Craig Godwin INC.
View Craig Godwin INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340492842.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.