CAMDEN, NJ —
OSHA Inspection: 36 APPLIANCES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of 36 APPLIANCES in 3516 FEDERAL STREET, CAMDEN, NJ 08105 (NAICS 453310). OSHA activity number 340493360.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 36 APPLIANCES
- Site address
- 3516 FEDERAL STREET
- City
- CAMDEN
- State
- NJ
- ZIP
- 08105
- Mailing
- 3516 FEDERAL STREET, CAMDEN, NJ 08105
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 453310
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.132 A
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) 36 Appliances - Maintenance area: Employees were exposed to chemical burns while mixing caustic soda beads (corrosive) with water, the mixture is used to clean stainless steel grids and other metal pieces on a daily basis. Occurred on or about 03/24/2015.
Recent events (1)
- — Z (S) $1200
1910.151 C
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) 36 Appliances - Maintenance area: The employer did not provide an eye wash station for quick drenching or flushing of the eyes when employees can come in contact with caustic soda (corrosive) at the time it is mixed with water, the mixture is used to clean stainless steel grids and other metal pieces on a daily basis. Occurred on or about 03/24/2015
Recent events (1)
- — Z (S) $0
1910.304 B03
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.304(b)(3): Ground-fault circuit interrupter was not installed for the protection of personnel. a) 36 Appliances - Maintenance area: The outlet located in the maintenance area did not have a Ground-Fault Circuit Interrupter (GFCI) to protect employees from electrical hazards while becoming in contact with wet or damp surfaces. Observed on or about 03/24/2015.
Recent events (1)
- — Z (S) $1200
1910.305 J02 VI
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(vi): A receptacle installed in a wet location where the product intended to be plugged into it was not to be attended while in use did not have an enclosure that was weatherproof with the attachment plug cap inserted or removed: (a) 36 Appliance - Maintenance area: The outlet located in the maintenance area did not have a cover to protect it against water or other liquids present around the area to protect employees from electrical hazards while coming in contact with wet or damp surfaces. Observed on or about 03/24/2015
Recent events (1)
- — Z (S) $0
1910.1200 H01
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) 36 Appliances - Maintenance area: The employer had not provided information and training to employees on chemicals they used in the workplace such as Caustic soda (Corrosive), on or about 03/24/2015
Recent events (1)
- — Z (S) $1200
1910.1200 E01
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) 36 Appliances - Maintenance area: The employer did not have a written hazard communication program for employees that handled chemicals such as caustic soda, on or about 01/15/2015.
Recent events (1)
- — Z (S) $0
1910.1200 G01
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a) 36 Appliances - Maintenance area: The employer did not have Safety Data Sheets (SDs) for each hazardous chemical such as but not limited to Caustic Soda beads, on or about 03/24/2015.
Recent events (1)
- — Z (S) $0
1910.1200 F05 I
- Issued
- Jun 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) 36 Appliances - Maintenance area: Plastic drum containers containing Caustic soda mixed with water were not labeled, observed on or about 03/24/2015.
Recent events (1)
- — Z (S) $0
More inspections at 36 Appliances
View 36 Appliances's full OSHA safety record →
More inspections in this industry (NAICS 453310)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340493360.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.