Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMPRISE CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EMPRISE CONSTRUCTION INC. in 506 3RD STREET, BROOKLYN, NY 11215 (NAICS 236116). OSHA activity number 340494103.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Emprise Construction INC. — free Get an email when a new federal OSHA severe-injury report for Emprise Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
506 3RD STREET
City
BROOKLYN
State
NY
ZIP
11215
Mailing
412 W 19TH STREET #5A, NEW YORK, NY 10011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
12
Ownership type
A

5 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2015
Abate by
Oct 13, 2015
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  a) 2nd floor kitchen:  An employee used an electric powered angle grinder to cut water pipes for kitchen installation. The angle grinder was designed to accommodate a guard for the cutting wheel, and was not equipped with such guard when in use. On or about 04/15/15.
Recent events (1)
  • — Z (S) $3500

1926.403 I02 I

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 30, 2015
Abate by
Oct 13, 2015
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.     a) Basement, electrical circuit breaker panels:     Employees used switches on circuit breaker panels to control electrical power to all floors. Energized parts of the panels were exposed and were not guarded against accidental contact by employees. On or about 04/15/15.
Recent events (1)
  • — Z (S) $3500

1926.404 B01 I

Serious Gravity 5 2 instances 7 exposed
Issued
Sep 30, 2015
Abate by
Oct 13, 2015
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  a) 2nd floor kitchen:  An employee used an electric powered angle grinder to cut water pipes for kitchen installation. The angle grinder was connected to an extension cord, which was routed to a nearby outlet device and was not provided with a ground fault circuit interrupter. On or about 04/15/15.  b) Basement:  Employees used an electric powered jackhammer to break concrete and rocks for basement expansion. The jackhammer was connected to an extension cord, which was routed to a nearby outlet device and was not provided with a ground fault circuit interrupter. On or about 04/15/15.
Recent events (1)
  • — Z (S) $3500

1926.404 F06

Serious Gravity 5 2 instances 7 exposed
Issued
Sep 30, 2015
Abate by
Oct 13, 2015
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.     a) 2nd floor kitchen:     An employee used an electric powered angle grinder to cut water pipes for kitchen installation. The angle grinder was connected to an extension cord, which was routed to a nearby outlet device and was missing a ground pin. On or about 04/15/15.  b) Basement:  Employees used an electric powered jackhammer to break concrete and rocks for basement expansion. The jackhammer was connected to an extension cord, which was routed to a nearby outlet device and was missing a ground pin. On or about 04/15/15.
Recent events (1)
  • — Z (S) $3500

1926.405 B01

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 30, 2015
Abate by
Oct 13, 2015
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed.     a) Basement, electrical outlet box:     Employees plugged extension cords into the outlets of an electrical outlet box for powering tools and temporary lightning. Unused openings in the outlet box were not effectively closed. On or about 04/15/15.
Recent events (1)
  • — Z (S) $3500

View Emprise Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340494103.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.