Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SNYDER INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SNYDER INDUSTRIES, INC. in 8 MATTALIANO DRIVE, PHILIPPI, WV 26416 (NAICS 326199). OSHA activity number 340494319.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Snyder Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Snyder Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8 MATTALIANO DRIVE
City
PHILIPPI
State
WV
ZIP
26416
Mailing
8 MATTALIANO DRIVE, PHILIPPI, WV 26416
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
11
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 23, 2015
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specify procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:       (a) 22 Foot Oven: Employees perform cleaning on the 22 foot oven, which has multiple energy sources such as gas and electric, and requires the control of hazardous energy by locking out the equipment. The energy control procedure lists the blue Maxon box as the sole isolating device. The blue Maxon box is not an energy isolating device, as determined on or about 03/25/2015.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.147 C04 II C

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:    (a) 22 Foot Oven: Employees perform cleaning on the 22 foot oven, which has multiple energy sources such as gas and electric, and requires the control of hazardous energy by locking out the equipment. The energy control procedure for the 22 foot oven did not outline the steps for placement, removal and transfer of lockout devices for the natural gas valve, as determined on or about 03/25/2015.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    (a) 22 Foot Oven: The authorized employee did not lockout the gas train before cleaning the 22 foot oven, which has multiple energy sources such as gas and electric that requires the control of hazardous energy, as determined on or about 03/25/2015.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D06

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  (a) 22 Foot Oven: Employees perform cleaning on the 22 foot oven, which has multiple energy sources such as gas and electric, and requires the control of hazardous energy by locking out the equipment. The authorized employee did not verify the isolation and deenergization of the gas had been accomplished, as determined on or about 03/25/2015.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Snyder Industries, INC.'s full OSHA safety record →