PHILIPPI, WV —
OSHA Inspection: SNYDER INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SNYDER INDUSTRIES, INC. in 8 MATTALIANO DRIVE, PHILIPPI, WV 26416 (NAICS 326199). OSHA activity number 340494319.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SNYDER INDUSTRIES, INC.
- Site address
- 8 MATTALIANO DRIVE
- City
- PHILIPPI
- State
- WV
- ZIP
- 26416
- Mailing
- 8 MATTALIANO DRIVE, PHILIPPI, WV 26416
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 11
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jun 23, 2015
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specify procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) 22 Foot Oven: Employees perform cleaning on the 22 foot oven, which has multiple energy sources such as gas and electric, and requires the control of hazardous energy by locking out the equipment. The energy control procedure lists the blue Maxon box as the sole isolating device. The blue Maxon box is not an energy isolating device, as determined on or about 03/25/2015. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.147 C04 II C
- Issued
- Jun 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: (a) 22 Foot Oven: Employees perform cleaning on the 22 foot oven, which has multiple energy sources such as gas and electric, and requires the control of hazardous energy by locking out the equipment. The energy control procedure for the 22 foot oven did not outline the steps for placement, removal and transfer of lockout devices for the natural gas valve, as determined on or about 03/25/2015. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Jun 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) 22 Foot Oven: The authorized employee did not lockout the gas train before cleaning the 22 foot oven, which has multiple energy sources such as gas and electric that requires the control of hazardous energy, as determined on or about 03/25/2015. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D06
- Issued
- Jun 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished: (a) 22 Foot Oven: Employees perform cleaning on the 22 foot oven, which has multiple energy sources such as gas and electric, and requires the control of hazardous energy by locking out the equipment. The authorized employee did not verify the isolation and deenergization of the gas had been accomplished, as determined on or about 03/25/2015. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Snyder Industries, INC.
View Snyder Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340494319.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.