Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRANCO CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FRANCO CONSTRUCTION LLC in 1908 VON HOFF DR., BATAVIA, IL 60510 (NAICS 238160). OSHA activity number 340494996.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Franco Construction LLC — free Get an email when a new federal OSHA severe-injury report for Franco Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
1908 VON HOFF DR.
City
BATAVIA
State
IL
ZIP
60510
Mailing
10155 SQUIRE DR., PLYMOUTH, IN 46563
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 7, 2015
Abate by
Apr 17, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.100(a):   Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  Employees were exposed to struck by hazards due to the lack of head protection while working below other employees removing shingles and other debris from the roof.  The employer did not ensure that head protection was worn as necessary.   Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1200

1926.102 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 7, 2015
Abate by
Apr 17, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.102(a)(1):     Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    Employees were exposed to eye injury from the lack of protective safety glasses while using handheld pneumatic nail guns to affix shingles to the roof of a residential property.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B04 I

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 7, 2015
Abate by
Apr 17, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.501(b)(4)(i):     Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    Employees were not protected from a fall through skylights while performing roofing operations at a residential property, exposing employees to a fall of at least 8' to the lower level.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1600
  • — Z (S) $1600

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 7, 2015
Abate by
Apr 17, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.501(b)(13):     Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     Employees were not protected from a fall while performing roofing operations at a residential property, exposing employees to falls ranging from 10' 8" to 19' 8".      Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 7, 2015
Abate by
Apr 17, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1):   Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   Employees used a portable metal extension ladder to access an 8/12 slope roof approximately 10 feet 8 inches above the ground. The ladder side rails did not extend at least 3 feet above the upper landing surface; they were extended approximately one foot above.   Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

View Franco Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340494996.