Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R/J GROUP, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of R/J GROUP, INC. in 431 CANAL STREET, NEW SMYRNA BEACH, FL 32168 (NAICS 238160). OSHA activity number 340495548.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R/J Group, INC. — free Get an email when a new federal OSHA severe-injury report for R/J Group, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
R/J GROUP, INC.
Site address
431 CANAL STREET
City
NEW SMYRNA BEACH
State
FL
ZIP
32168
Mailing
4244 JACKSON ST, PORT ORANGE, FL 32127
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
34
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 7 exposed
Issued
Aug 19, 2015
Penalty
Initial $4,900 · Current $3,675 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a. On or about March 25, 2015, employees were permitted to work within 5-foot of the 13.2 KV energized power lines that were not protected against electrical shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means, an employee was electrocuted when the 20-foot iron channel rod he was removing came into contact with the energized power line.
Recent events (2)
  • — I (S) $3675
  • — Z (S) $4900

1926.416 A03

Serious Gravity 10 1 instance 7 exposed
Issued
Aug 19, 2015
Penalty
Initial $4,900 · Current $3,675 Reduced
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit:    a. On or about March 25, 2015, the employer did not conduct a hazard assessment, which would have identified a 3-phase overhead power line system. The overhead power line system was not protected, in that the utilities company was not contacted so the lines could be de-energized or sleeved, which resulted in an electrocution.
Recent events (2)
  • — I (S) $3675
  • — Z (S) $4900

1926.502 F01 I

Serious Gravity 10 1 instance 7 exposed
Issued
Aug 19, 2015
Penalty
Initial $4,900 · Current $1,000 Reduced
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge:    a. On or about March 25, 2015, on a 22-foot commercial buildings roof, a warning line system was not established 6-foot back from the edge, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4900

View R/J Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340495548.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.