OSHA Inspection: SALOOMEY CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SALOOMEY CONSTRUCTION, INC. in 57 RALSTON STREET, KEENE, NH 03431 (NAICS 236116). OSHA activity number 340503440.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Saloomey Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Saloomey Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
57 RALSTON STREET
City
KEENE
State
NH
ZIP
03431
Mailing
PO BOX 1203, OTIS, MA 01253
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
2
Ownership type
A

8 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 40 exposed
Issued
Jun 1, 2015
Abate by
Jun 11, 2015
Penalty
Initial $2,200 · Current $1,320 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:    a. Site- The controlling contractor failed to ensure that their employees and employees under their control were protected from fall, struck by, scaffold collapse, powered industrial truck, fire, trip, and electrical hazards where accident prevention programs were not initiated and maintained at the site.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $2200

1926.20 B02

Serious Gravity 5 1 instance 40 exposed
Issued
Jun 1, 2015
Abate by
Jun 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a. Site- The controlling contractor failed to ensure that their employees and employees under their control were protected from fall, struck by, scaffold collapse, powered industrial truck, fire, trip, and electrical hazards where inspections of the jobsite were not conducted by a competent person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.25 A

Serious Gravity 1 1 instance 40 exposed
Issued
Jun 1, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,320 · Current $800 Reduced
29 CFR 1926.25(a): During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:    Site- Employees and employees under the control of the controlling contractor were not protected from trip and fire hazards where scrap lumber with protruding nails was not kept clear of work areas, passageways, and stairs in buildings A and B.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1320

1926.34 C

Serious Gravity 5 1 instance 40 exposed
Issued
Jun 1, 2015
Abate by
Jun 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency:  a. Building A and B- Employees and employees under the control of the controlling contractor were not protected from trip hazards and instant access to emergency medical services where exit routes were not free of all obstructions or impediments. The fourth and third floors of building A where stocked with sheetrock lining both sides of the hallways reducing the hall way width to less than 28 inches. The first floor entrance to building B had metal door frames stored in the exit route causing a trip hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.150 C01 I

Other-than-serious 1 instance 20 exposed
Issued
Jun 1, 2015
Penalty
Initial $1,320 · Current $0 Reduced
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:    a. Building B- Employees and employees under the control of the controlling contractor were not protected from fire and entrapment hazards where fire extinguishers were not available on each floor of the building.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1320

1926.501 B04 I

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 1, 2015
Abate by
Jun 5, 2015
Penalty
Initial $2,200 · Current $1,320 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    a. Building B- Employees were not protected from falls between approximately 10 to 30 feet through floor holes.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $2200

1926.501 B14

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:  a. Building B- Employees and employees under the control of the controlling contractor were not protected from falls between approximately 10 and 40 feet where wall openings were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01 I

Serious Gravity 1 1 instance 20 exposed
Issued
Jun 1, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,320 · Current $800 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:     a. Building A and B- Employees and employees under the control of the controlling contractor were not protected from slip and trip hazards where interior stairways did not have a handrail.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1320

View Saloomey Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340503440.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.