OSHA Inspection: QUALITY SIDING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QUALITY SIDING in 4 TWOMEY DRIVE, NEWBURYPORT, MA 01950 (NAICS 238170). OSHA activity number 340504182.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Siding — free Get an email when a new federal OSHA severe-injury report for Quality Siding is published. One employer, no account, unsubscribe in one click.
Establishment
QUALITY SIDING
Site address
4 TWOMEY DRIVE
City
NEWBURYPORT
State
MA
ZIP
01950
Mailing
96 GROTON ROAD, TYNGSBORO, MA 01879
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    (a) Location - 4 Twomey Drive, Newburyport, MA:  On or about 3/30/15, employees were working on a scaffold 20 feet high and were not protected from falling.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.452 J02

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 24, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    (a) Location - 4 Twomey Drive, Newburyport, MA:  On or about 3/30/15, the pump-jack scaffold poles were secured at the bottom with wood and not according to manufacturer's specification.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 24, 2015
Penalty
Initial $1,600 · Current $900 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    (a) Location - 4 Twomey Drive, Newburyport, MA:  On or about 3/30/15, employees were using a 12 foot extension ladder to access the scaffold and the side rails did not extend 3 feet above the landing surface.