CANON CITY, CO —
OSHA Inspection: LINDER CHEVROLET, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of LINDER CHEVROLET, INC. in 2805 FREMONT DRIVE, CANON CITY, CO 81212 (NAICS 441110). OSHA activity number 340506088.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LINDER CHEVROLET, INC.
- Site address
- 2805 FREMONT DRIVE
- City
- CANON CITY
- State
- CO
- ZIP
- 81212
- Mailing
- 2805 FREMONT DRIVE, CANON CITY, CO 81212
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441110
- Employees
- 36
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 C01
- Issued
- Apr 7, 2015
- Abate by
- May 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about March 24, 2015, and at times prior, the employer had not established and implemented a written respiratory program for spray booth operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Apr 7, 2015
- Abate by
- May 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On March 24, 2015, and at times prior, an employee working in the spray booth wore a 3M 5000 series half-face respirator without being provided a medical evaluation to ensure that they were medically fit to wear a respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F01
- Issued
- Apr 7, 2015
- Abate by
- May 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On March 24, 2015, and at times prior, the employer did not provide employees working in the spray booth a quantitative or qualitative fit test to ensure proper fit of tight fitting respirators.