Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SCHANKUSKI CARPENTERS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCHANKUSKI CARPENTERS, LLC in 3619 14TH. ST., NW, WASHINGTON, DC 20005 (NAICS 238350). OSHA activity number 340508498.

Watch Schankuski Carpenters, LLC — free Get an email when a new federal OSHA severe-injury report for Schankuski Carpenters, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3619 14TH. ST., NW
City
WASHINGTON
State
DC
ZIP
20005
Mailing
5110 KENEBUNK TERR., COLLEGE PARK, MD 20740
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
3
Ownership type
A

9 citations on file for this inspection.

1926.304 F

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.304(f): Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery:    a)  Front of Building - On or about 03/30/2015, pursuant to American National Standards Institute, 01.1-1961, 4.1.2(c), a Ryobi 10 inch portable table saw (serial #84011245) used to cut and rip architectural panels was not provided with a spreader.   b)  Front of Building - On or about 03/30/2015, pursuant to American National Standards Institute, 01.1-1961, 4.1.2(b), a Ryobi 10 inch portable table saw (serial #84011245) used to cut and rip architectural panels was not provided with non-kickback fingers or dogs.   c)  Front of Building - On or about 03/30/2015, pursuant to American National Standards Institute, 01.1-1961, 3.1.3(c), a Ryobi 10 inch portable table saw (serial #84011245) used to cut and rip architectural panels was not provided with a magnetic restart device whereby employee would be protected from the unexpected restart of the saw in the event of an power interruption.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2000

1926.304 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:   a)  Front of Building - On or about 03/30/2015, a Ryobi 10 inch portable table saw (serial #84011245) used to cut and rip architectural panels was not provided with a hood or top guard to protect employees from accidental contact with the saw's rotating blade.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:   a)  Front of Building  On or about 03/31/2015, a portable table saw was not provided with either assured equipment grounding conductor program or ground fault circuit interrupters thereby exposing carpenters to a 120 volt shock hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a)  Front of Building  On or about 03/31/2015, a heavy-duty extension cord used to power a portable circular saw was not provided with a continuous ground.
Recent events (1)
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   a)  Front of Building  On or about 03/31/2015, the flexible cord entering a Makita portable table saw was not provided with strain relief.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used.  a)  On or about 03/31/2015, the protective shielding of a flexible cord entering the housing of a Makita portable table saw was cut thereby exposing the cords interior copper wiring to employee contact.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.451 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall:   a)  Front of Building  On or about 03/31/2015, workers working under a pump jack scaffold system were not protected from falling objects, including tools and materials, by screens, toe boards or other acceptable methods.
Recent events (1)
  • — Z (S) $2000

1926.452 J03

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(3): When guardrails were used for fall protections, a workbench meeting the requirements was not in use:   a)  Front of Building  On or about 03/31/2015, two carpenters were exposed to a 19 foot fall from the platform of a pump jack scaffold system which had a work rest located only 33 inches above the scaffold platform and no other toprail or midrail had been provided.
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed:   a)  Front of Building  On or about 03/31/2015, a carpenter was exposed to a four foot fall from a step ladder which he had left folded together and had leaned up against a building.
Recent events (1)
  • — Z (O) $0

MACY'S

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340508498.