WASHINGTON, DC —
OSHA Inspection: D & O CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D & O CONSTRUCTION LLC in 2812 36TH STREET PL NW, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 340509041.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D & O CONSTRUCTION LLC
- Site address
- 2812 36TH STREET PL NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- 24 BRIAN CT, GAITHERSBURG, MD 20877
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Jun 26, 2015
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On March 31, 2015 and at times prior thereto; second level; employees framing and sheathing the remodeled residential home were observed sitting or working off the rafters without fall protection in place to prevent them from falling 35 feet to ground level. b) On March 31, 2015 and at times prior thereto; second floor area; employees were exposed to unguarded open floors exposing to a 10 foot fall to the lower level.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1926.1052 C01 II
- Issued
- Jun 26, 2015
- Penalty
- Initial $1,600 · Current $900 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) On March 31, 2015 and at times prior thereto; second floor; the stairs used to access the upper floors were not properly guarded exposing employees to a 54 inch fall to the lower platform.
Recent events (2)
- — I (S) $900
- — Z (S) $1600