Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M. J. HARRIS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M. J. HARRIS INC. in 2620 N. WESTWOOD BLVD., POPLAR BLUFF, MO 63901 (NAICS 236220). OSHA activity number 340510205.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M. J. Harris INC. — free Get an email when a new federal OSHA severe-injury report for M. J. Harris INC. is published. One employer, no account, unsubscribe in one click.
Establishment
M. J. HARRIS INC.
Site address
2620 N. WESTWOOD BLVD.
City
POPLAR BLUFF
State
MO
ZIP
63901
Mailing
ONE RIVERCHASE RIDGE SUITE 300, BIRMINGHAM, AL 35244
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 5 4 instances 20 exposed
Issued
Apr 7, 2015
Abate by
May 1, 2015
Penalty
Initial $2,888 · Current $2,022 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures:  JOB SITE: 2620 N. Westwood Drive, Poplar Bluff, MO 63901, on or about 3/25/2015, the covers to the electrical 480v panel boxes were left open.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $2021.6
  • — Z (S) $2888

1926.403 I02 III

Serious Gravity 5 1 instance 20 exposed
Issued
Apr 7, 2015
Abate by
May 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.403(i)(2)(iii): Entrances to rooms and other guarded locations containing exposed live parts operating at 600 volts, nominal, or less were not marked with conspicuous warning signs forbidding unqualified persons to enter:  In the alternative 1910.303(g)(2)(iii):  JOB SITE: 2620 N. Westwood Drive, Poplar Bluff, MO 63901, on or about 3/25/2015, at this facility, entrances to rooms and other guarded locations containing exposed live parts operating at 600 volts, nominal, or less were not marked with conspicuous warning signs forbidding unqualified persons to enter.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 2 instances 20 exposed
Issued
Apr 7, 2015
Abate by
May 1, 2015
Penalty
Initial $2,310 · Current $1,617 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:  JOB SITE: 2620 N. Westwood Drive, Poplar Bluff, MO 63901, on or about 3/25/2015, at this construction site, the employers installed two (2) electrical trees to provide electrical power to portable power hand tools, and fans, were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.  The workers were exposed to an electrical hazard.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $1617
  • — Z (S) $2310

View M. J. Harris INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340510205.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.