Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EDGE ENERGY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EDGE ENERGY in 450 N ST. NW, WASHINGTON, DC 20004 (NAICS 221114). OSHA activity number 340510544.

Watch Edge Energy — free Get an email when a new federal OSHA severe-injury report for Edge Energy is published. One employer, no account, unsubscribe in one click.
Establishment
EDGE ENERGY
Site address
450 N ST. NW
City
WASHINGTON
State
DC
ZIP
20004
Mailing
6854 DISTRIBUTION DR, BELTSVILLE, MD 20705
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.404 F06

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.    On or about April 2, 2015 and at times prior thereto, employees were exposed to electrical hazards because the grounding pin had been removed from an electrical extension cord that was attached to a 6 gallon porter-cable air compressor.     Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $2100
  • — Z (S) $3500

1926.405 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap.    On or about April 2, 2015 and at times prior thereto, employees were exposed to electrical hazards because the power cord of a 5 gallon porter-cable air compressor was spliced with an electrical extension cord covered with electrical tape.       Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).    On or about April 2, 2015 and at times prior thereto employees were exposed to fall hazards while installing solar panels on the two story residence without any fall protection, exposing the employees to a fall distance of approximately 19' to the ground.     Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

MACY'S