Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLEAN MACHINE POWER WASH INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CLEAN MACHINE POWER WASH INC. in 224 COLD SPRING AVE., WEST SPRINGFIELD, MA 01090 (NAICS 561790). OSHA activity number 340511815.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clean Machine Power Wash INC. — free Get an email when a new federal OSHA severe-injury report for Clean Machine Power Wash INC. is published. One employer, no account, unsubscribe in one click.
Site address
224 COLD SPRING AVE.
City
WEST SPRINGFIELD
State
MA
ZIP
01090
Mailing
P.O. BOX 463, WEST SPRINGFIELD, MA 01090
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
40
Ownership type
A

7 citations on file for this inspection.

1910.132 A

Serious Gravity 10 2 instances 32 exposed
Issued
Jun 10, 2015
Abate by
Jul 28, 2015
Penalty
Initial $4,900 · Current $2,450 Reduced

Hazardous substances 1460

29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a) At a customer job site: On or about March 24, 2015, the employer did not ensure a power washing employee used appropriate protective gloves, neoprene or PVC, while applying a hydrofluoric acid-containing solution of CM-X and water which resulted in the employee receiving chemical burns to his hands.      b) In the chemical dispensing area at 224 Cold Spring Avenue West Springfield, MA: On or about April 7, 2015, the employer did not ensure an employee used appropriate protective gloves, neoprene or PVC, while exposed to a hydrofluoric acid-containing cleaning solution, CM-X, during a chemical transfer from a 55 gallon drum to a 5 gallon container.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 10, 2015
Abate by
Jul 28, 2015
Penalty
Initial $2,975 · Current $0 Reduced

Hazardous substances 1460

29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    In the vehicle and chemical dispensing bay at 224 Cold Spring Avenue Springfield, MA: On or about April 7, 2015, the employer did not ensure employees used appropriate eye and face protection while dispensing a hydrofluoric acid containing cleaning solution, CM-X, from a 55 gallon drum into a 5 gallon container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2975

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 10, 2015
Penalty
Initial $2,529 · Current $1,265 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  In the chemical storage and truck bay at 224 Cold Spring Avenue West Springfield, MA: On or about April 7, 2014, the employer did not ensure a work rest guard on an electric grinding wheel was properly adjusted with a maximum opening of one eighth inch.
Recent events (2)
  • — I (S) $1264.5
  • — Z (S) $2529

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  In the cleaning chemical dispensing and truck maintenance bay at 224 Cold Spring Avenue West Springfield, MA: On or about April 7, 2015, the employer did not ensure a tongue guard was installed on the electric bench grinder and adjusted on the top of the peripheral member to a maximum distance of one fourth inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01 I

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 10, 2015
Penalty
Initial $2,380 · Current $1,190 Reduced

Hazardous substances 1460

29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:  In the office entrance at 224 Cold Spring Avenue West Springfield, MA: On or about April 3, 2015, the employer did compile a complete list of hazardous chemicals known to be present in the workplace in that the list did not contain a hydrofluoric acid-containing cleaner, CM-X, used by pressure washer employees.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.1200 F10

Serious Gravity 5 2 instances 8 exposed
Issued
Jun 10, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 1460

29 CFR 1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were prominently displayed on the container and legible in the work area throughout each work shift:  In the chemicals dispensing area at 224 Cold Spring Avenue West Springfield, MA: On or about April 3, 2015, the employer did not ensure workplace labels were prominently displayed or legible on 55 gallon drums of CM-X and AB-1, hydrofluoric-acid containing cleaning solutions.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 10, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 1460

29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  In the entrance to the office area at 224 Cold Spring Avenue West Springfield, MA: On or about April 3, 2015, the SDS binder in the workplace did not contain an SDS for CM-X, a hydrofluoric-acid containing cleaning product used daily by employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340511815.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.