Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. FOREST SERVICE-COCONINO NATIONAL FOREST

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. FOREST SERVICE-COCONINO NATIONAL FOREST in 1824 S. THOMPSON STREET, FLAGSTAFF, AZ 86001 (NAICS 924120). OSHA activity number 340513332.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Forest Service-Coconino National Forest — free Get an email when a new federal OSHA severe-injury report for U.S. Forest Service-Coconino National Forest is published. One employer, no account, unsubscribe in one click.
Site address
1824 S. THOMPSON STREET
City
FLAGSTAFF
State
AZ
ZIP
86001
Mailing
1824 S. THOMPSON STREET, FLAGSTAFF, AZ 86001
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
233
Ownership type
D

8 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 20 exposed
Issued
Aug 19, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  (a) Coconino National Forest: On or about 31 March 2015 and at times prior thereto, the agency did not administer a continuing, effective hearing conservation program.
Recent events (1)
  • — Z (S) $0

1910.95 D01

Serious Gravity 5 1 instance 20 exposed
Issued
Aug 19, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:  (a) Coconino National Forest: On or about 31 March 2015 and at times prior thereto, the agency did not develop and implement a monitoring program for noise exposure. Employees are exposed to high noise levels generated by gas-powered tools and heavy equipment. In addition, Law Enforcement Officers are exposed to high impact noise levels during firearm qualifications.
Recent events (1)
  • — Z (S) $0

1910.95 G06

Serious Gravity 5 1 instance 20 exposed
Issued
Aug 19, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :  (a) Coconino National Forest: On or about 31 March 2015 and at times prior thereto, the agency did not offer and obtain annual audiograms for employees required to be covered by the agency's hearing conservation program.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  (a) Coconino National Forest: On or about 31 March 2015 and at times prior thereto, annual fit testing was not performed for employee(s) who are required to wear an elastomeric half-mask respirator during cleaning of water system chlorinators.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Repeat Gravity 1 1 instance 2 exposed
Issued
Aug 19, 2015
Abate by
Sep 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Archaeology Lab: On or about 31 March 2015 and at times prior thereto, power strips (relocatable power taps) were daisy-chained and plugged into extension cords. Per the UL White Book, a) Relocatable power taps are intended to be directly connected to a permanently installed branch circuit receptacle and, b) Relocatable power taps are not intended to be series connected (daisy chained) to other relocatable power taps or to extension cords.   The U.S. Forest Service was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 982198, citation number 2, item number 3 and was affirmed as a final order on December 19, 2014, with respect to a workplace located at 29835 Valyermo Road, Valyermo, CA 93563.  The U.S. Forest Service was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 957451, citation number 2, item number 5, and was affirmed as a final order on April 7, 2014, with respect to a workplace located at 1634 Black Canyon Rd., Goose Valley Fire Station, Ramona, CA 92065.
Recent events (1)
  • — Z (R) $0

1910.132 D02

Other-than-serious 1 instance 20 exposed
Issued
Aug 19, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  (a) Coconino National Forest: On or about 31 March 2015 and at times prior thereto, the agency failed to verify, through a written certification, that a workplace hazard assessment had been performed.
Recent events (1)
  • — Z (O) $0

1910.134 C

Other-than-serious 1 instance 5 exposed
Issued
Aug 19, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  (a) Coconino National Forest: On or about 31 March 2015 and at times prior thereto, the agency did not develop and implement a written site-specific respirator program. Elastomeric half-mask respirators were used during the cleaning of chlorinators for the water systems.
Recent events (1)
  • — Z (O) $0

1910.134 M02 I

Other-than-serious 1 instance 5 exposed
Issued
Aug 19, 2015
Abate by
Sep 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(m)(2)(i): The employer did not establish a record of the qualitative and quantitative fit tests administered to an employee which included the information required by 29 CFR 1910.134(m)(2)(i)(A) through (m)(2)(i)(E):  (a) Coconino National Forest: On or about 31 March 2015 and at times prior thereto, a record of respirator qualitative fit tests was not established for employees who maintain the agency's water systems.
Recent events (1)
  • — Z (O) $0

View U.S. Forest Service-Coconino National Forest's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340513332.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.