OSHA Inspection: SEATON CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SEATON CORPORATION in 1601 VALDOSTA HIGHWAY, HOMERVILLE, GA 31634 (NAICS 561320). OSHA activity number 340513753.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Seaton Corporation — free Get an email when a new federal OSHA severe-injury report for Seaton Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
SEATON CORPORATION
Site address
1601 VALDOSTA HIGHWAY
City
HOMERVILLE
State
GA
ZIP
31634
Mailing
1601 VALDOSTA HIGHWAY, HOMERVILLE, GA 31634
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
561320
Employees
88
Ownership type
A

5 citations on file for this inspection.

1910.217 C01 I

Serious Gravity 10 2 instances 3 exposed
Issued
Sep 24, 2015
Abate by
Oct 21, 2015
Penalty
Initial $7,000 · Current $5,500 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):      b) Ammo Department, on or about April 1, 2015 and times prior to, the part revolution, Rousselle punch press did not have any type of safe guarding at the point of operation, thus exposing employees to amputation hazards.
Recent events (3)
  • — F (S) $5500
  • — C (S) $7000
  • — Z (S) $7000

1910.217 F02

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 24, 2015
Abate by
Oct 21, 2015
Penalty
Initial $7,000 · Current $4,250 Reduced
29 CFR 1910.217(f)(2): Operator(s) were not trained and instructed in the safe method of work before starting work on mechanical power press(es):    a) Press Areas Throughout the Facility - On or about March 25, 2015, and at times prior to, the employer did not ensure that employees operating presses were trained in the safe work methods of operating presses, thus exposing employees to amputation hazards at the point of operation.
Recent events (3)
  • — F (S) $4250
  • — C (S) $7000
  • — Z (S) $7000

1910.219 C02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 24, 2015
Abate by
Oct 21, 2015
Penalty
Initial $5,000 · Current $4,000 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    a) Production Area, Ammo wire department,  on or about March 31, 2015 and at times prior to, the rotating horizontal shaft on the AM1108 cover link wire form motor was not covered, exposing employees to entanglement and frictional burns.
Recent events (3)
  • — F (S) $4000
  • — C (S) $5000
  • — Z (S) $5000

1910.303 B02

Deleted Other-than-serious 1 instance 1 exposed
Issued
Sep 24, 2015
Abate by
Oct 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  Paint Chain behind B-Line, on or about March 31, 2015 and times prior to, a duplex electrical receptacle designed to be mounted was being used as a pendant to power fans and a parts washer, thus exposing employees to electrical hazards.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.305 B02 I

Deleted Other-than-serious 1 instance 1 exposed
Issued
Sep 24, 2015
Abate by
Oct 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a) Behind B-Line Assembly near the Old Maintenance Shop, on or about April 1, 2015, part of the front cover was missing from the 280-volts electrical junction box, exposing employees to electrical hazards.
Recent events (3)