Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PAPCO INDUSTRIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PAPCO INDUSTRIES, INC. in 245 PEGASUS AVE, NORTHVALE, NJ 07647 (NAICS 339999). OSHA activity number 340514975.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Papco Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Papco Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
245 PEGASUS AVE
City
NORTHVALE
State
NJ
ZIP
07647
Mailing
245 PEGASUS AVE, NORTHVALE, NJ 07647
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
Employees
35
Ownership type
A

10 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 4, 2015
Abate by
Oct 24, 2015
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use  respirators, before the employees were required to use the respirator in the workplace:    a) Facility: A medical evaluation was not provided for the employees who were required to use half-face respirators, on or about 04/06/15.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.157 C01

Serious Gravity 1 3 instances 9 exposed
Issued
Sep 4, 2015
Abate by
Oct 1, 2015
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) Manufacturing Area, next to the Assembling Line: The area marked to show the location for a fire extinguisher was missing a fire extinguisher, on or about 04/06/15.  b) Manufacturing Area, between Assembling Line and Welding Area: The area marked to show the location for a fire extinguisher was missing a fire extinguisher, on or about 04/06/15.  c) Welding Area, Material Storage Rack: The area marked to show the location for a fire extinguisher was missing a fire extinguisher, on or about 04/06/15.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.212 B

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 4, 2015
Abate by
Oct 1, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(b): Machine designed for fixed location was not securely anchored to prevent walking or moving:  a) Manufacturing Area: Ridgid Vertical Drill Press was not anchored to prevent moving, on or about 04/06/15.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.253 B02 II

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 4, 2015
Abate by
Oct 1, 2015
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:      a): Loading Area: Oxygen and Carbon Dioxide/Argon cylinders were stored in a distance of about 3 - 6 feet from combustible materials including Interlac 665FD, Zinc Metal Pigment, and Carboline Thinner, on or about 04/06/15.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.253 B04 I

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 4, 2015
Abate by
Oct 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire  a) Loading Area: An Oxygen cylinder was stored together with two Acetylene cylinders, on or about 04/06/15.  b) Loading Area: An Oxygen cylinder was stored in close proximity from Propane tanks, on or about 04/06/15
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Sep 4, 2015
Abate by
Oct 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer:    a) Facility: A written respiratory protection program was not established in the workplace where respirators were required to use by the employer and where the employees worked with hazardous chemicals including, but not limited to, Interlac 665FD, Zinc Metal Pigment, and Interplate 937 Part B, on or about 04/07/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K

Other-than-serious 1 instance 2 exposed
Issued
Sep 4, 2015
Abate by
Oct 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training to employees who are required to use respirators:    a) Facility: A comprehensive training was not provided to employees who are required to use respirators and worked with hazardous chemicals including, but not limited to, Interlac 665FD, Zinc Metal Pigment, and Interplate 937 Part B, on or about 04/07/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 4 exposed
Issued
Sep 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) Manufacturing Area: Employees were not provided with Appendix D to 29 CFR 1910.134 while used respirators voluntarily, on or about 04/06/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 9 exposed
Issued
Sep 4, 2015
Abate by
Oct 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met    a) Facility: Written  Hazard Communication Program was not maintained at the workplace were employees worked with hazardous chemicals including, but not limited to, Interlac 665FD, Zinc Metal Pigment, and Interplate 937 Part B, on or about 04/07/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 9 exposed
Issued
Sep 4, 2015
Abate by
Oct 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:      a) Facility: Effective information and training was not provided to employees who worked with hazardous chemicals including, but not limited to, Interlac 665FD, Zinc Metal Pigment, and Interplate 937 Part B, on or about 04/07/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Papco Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340514975.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.