OSHA Inspection: ARMY CORPS OF ENGINEERS, DEXTER DAM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARMY CORPS OF ENGINEERS, DEXTER DAM in 39149 PENGRA RD., LOWELL, OR 97452 (NAICS 221111). OSHA activity number 340515097.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Army Corps of Engineers, Dexter DAM — free Get an email when a new federal OSHA severe-injury report for Army Corps of Engineers, Dexter DAM is published. One employer, no account, unsubscribe in one click.
Site address
39149 PENGRA RD.
City
LOWELL
State
OR
ZIP
97452
Mailing
211 E. 7TH AVE., SUITE 480, EUGENE, OR 97401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221111
Employees
20000
Ownership type
D

4 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 1 instance 13 exposed
Issued
Sep 25, 2015
Abate by
Oct 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Dexter Dam-  (a) The duplex receptacle, located in the entryway box area, had water dripping from the device.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 20 exposed
Issued
Sep 25, 2015
Abate by
Oct 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  Dexter Dam-  (a) The DX 20T Gantry Cranes indicator lamp had exposed live parts of 110 volts, exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.304 G02 II

Serious Gravity 5 1 instance 20 exposed
Issued
Sep 25, 2015
Abate by
Oct 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(2)(ii): The neutral conductor of a single-phase, three-wire system was not grounded.  Dexter Dam-  (a) The 110 volt receptacle, located on the downstream side of the dam, was tested and had an open ground.
Recent events (1)
  • — Z (S) $0

1910.212 A05

Repeat Gravity 5 1 instance 20 exposed
Issued
Sep 25, 2015
Abate by
Oct 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    Dexter Dam-  (a) The Hartzell ventilation fan blades were exposed through 5/8" openings on the guard, exposing workers to serious injuries.   The Army Corps of Engineers was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent standard 29 CFR 1910. 212(a)(5), which was contained in OSHA Inspection Number 96892, Citation Number 1, Item Number 6, and was affirmed as a final order on 09 /16/2011 with respect to a work place located at, Umatilla, OR.  Note: Abatement certification and supporting documentation are required for these items.
Recent events (1)
  • — Z (R) $0