Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMIGO ELECTRIC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMIGO ELECTRIC, INC. in 5570 CONFETTI DR, EL PASO, TX 79912 (NAICS 238210). OSHA activity number 340520246.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amigo Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Amigo Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5570 CONFETTI DR
City
EL PASO
State
TX
ZIP
79912
Mailing
10953 LAKEWOOD AVE, EL PASO, TX 79935
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 28, 2015
Abate by
Sep 17, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  Construction Site: A temporary romex wire was used to provide power from a panel box to a receptacle, this condition exposed employees to an electrical shock.
Recent events (1)
  • — Z (S) $1600

1926.405 G01 III B

Serious Gravity 1 2 instances 3 exposed
Issued
Aug 28, 2015
Abate by
Sep 17, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.405(g)(1)(iii)(B): 29 CFR 1926.405(g)(1)(iii)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  Construction site:  Flexible cords were run on through holes on the top and bottom sides of an apartment wall, this condition exposed employees to an electrical shock hazard.
Recent events (1)
  • — Z (S) $1200

1926.405 J01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 28, 2015
Abate by
Sep 17, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.405(j)(1): 29 CFR 1926.405(j)(1):  Fixtures, lampholders, lamps, rosettes, and receptacles had live parts exposed to employee contact.  Construction Site: A receptacle at the construction site was used to power portable hand tools and did not have a pendant to the protect the employees from live parts, this condition exposed employees to a shock hazard.