Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARROW FARMS OF NEW YORK, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARROW FARMS OF NEW YORK, INC. in 500 N. PETERBORO STREET, CANASTOTA, NY 13032 (NAICS 424480). OSHA activity number 340520972.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arrow Farms of NEW York, INC. — free Get an email when a new federal OSHA severe-injury report for Arrow Farms of NEW York, INC. is published. One employer, no account, unsubscribe in one click.
Site address
500 N. PETERBORO STREET
City
CANASTOTA
State
NY
ZIP
13032
Mailing
57 NEW ENGLAND PRODUCE CENTER, CHELSEA, MA 02150
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424480
Employees
25
Ownership type
A

9 citations on file for this inspection.

1910.157 G02

Serious Gravity 1 15 instances 15 exposed
Issued
Apr 20, 2015
Abate by
May 23, 2015
Penalty
Initial $1,200 · Current $400 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    a)  At the establishment, on or about 4/7/15:  Annual training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting.    *ABATEMENT NOTE:  By this date the employer must either correct the alleged violation or implement a Fire Safety Policy as outlined in 29 CFR 1910.38 and 29 CFR 1910.39 which includes the evacuation requirements of 29 CFR 1910.157(b).    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $400
  • — C (S) $1200
  • — Z (S) $1200

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 20, 2015
Abate by
May 23, 2015
Penalty
Initial $2,000 · Current $667 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip points/pinch points:    a)  Plant 1, Re-pack Line, on or about 4/7/15:  Ingoing nip points/pinch points on the sizing chain and pulleys on both sides of the machine were not guarded.    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $667
  • — C (S) $2000
  • — Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 20, 2015
Abate by
May 23, 2015
Penalty
Initial $2,000 · Current $667 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)  Plant 1, Re-pack Line, on or about 4/7/15:  Pulleys driving an inclined conveyor for the re-pack line were not guarded.    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $666.5
  • — C (S) $2000
  • — Z (S) $2000

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 20, 2015
Abate by
May 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  a)  Plant 1, Re-pack Line, on or about 4/7/15:  V belt driving an inclined conveyor for the re-pack line was not guarded.  Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 20, 2015
Abate by
May 23, 2015
Penalty
Initial $2,000 · Current $667 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed:    a)  Plant 1, Re-pack Line, on or about 4/7/15:  Chain and sprockets driving an inclined conveyor for the re-pack line were not guarded.    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $666.5
  • — C (S) $2000
  • — Z (S) $2000

1910.303 B01

Serious Gravity 1 2 instances 1 exposed
Issued
Apr 20, 2015
Abate by
Apr 30, 2015
Penalty
Initial $1,200 · Current $400 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause serious physical harm to employees:    a)  Plant 2, Tool Room, on or about 4/7/15:  Two electrical control boxes for the oil pump were not provided with covers.    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $400
  • — C (S) $1200
  • — Z (S) $1200

1910.305 G01 IV A

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 20, 2015
Penalty
Initial $1,200 · Current $400 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a)  Plant 2, Tool Room, on or about 4/7/15:  A strip outlet used for powering battery chargers and portable tools was attached to a workbench and being used as permanent wiring.    b)  Plant 1, on or about 4/7/15:  A blue extension cord providing current to a duplex outlet and switch for lights on the JASA packing machine was strung overhead and being used as permanent wiring.    Abatement certification must be submitted for instance b.
Recent events (3)
  • — J (S) $400
  • — C (S) $1200
  • — Z (S) $1200

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a)  Plant 2, Tool Room, on or about 4/7/15:  Flexible cord providing current to a strip outlet on the workbench was not provided with strain relief and subjecting the conductors to abrasions.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.37 A04

Other-than-serious 2 instances 4 exposed
Issued
Apr 20, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  a)  Plant 3, on or about 4/7/15:  Emergency lighting was not functioning.  b)  Plant 2, Tool Room, on or about 4/7/15:  Emergency lighting was not functioning.  Abatement certification must be submitted for these items.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340520972.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.