Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RENAISSANCE MOVING & STORAGE, INC., AND LIVINGSTON MOVING & STORAGE, INC., AN INTEGRATED ENTERPRISE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RENAISSANCE MOVING & STORAGE, INC., AND LIVINGSTON MOVING & STORAGE, INC., AN INTEGRATED ENTERPRISE in 26206 ROUTE 37, WATERTOWN, NY 13601 (NAICS 493110). OSHA activity number 340524578.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Renaissance Moving & Storage, INC., and Livingston Moving & Storage, INC., an Integrated Enterprise — free Get an email when a new federal OSHA severe-injury report for Renaissance Moving & Storage, INC., and Livingston Moving & Storage, INC., an Integrated Enterprise is published. One employer, no account, unsubscribe in one click.
Site address
26206 ROUTE 37
City
WATERTOWN
State
NY
ZIP
13601
Mailing
26206 ROUTE 37, WATERTOWN, NY 13601
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
9
Ownership type
A

7 citations on file for this inspection.

1910.23 A08

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
May 22, 2015
Abate by
Jul 10, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:  a) Parking lot, on or about 3/31/2015: Employees walking through the parking lot were exposed to a trip hazard due to a missing drainage grate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.36 D01

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
May 22, 2015
Abate by
Jun 4, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a) Back Door of P1 Building, on or about 3/31/2015: Emergency exit door was not able to be opened from the inside, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.215 A04

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2015
Abate by
Jun 4, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) Maintenance Shop, on or about 3/31/2015: Employee operated a Delta 6" Bench Grinder with the abrasive wheel work rest not adjusted to 1/8 of an inch, exposing employee to a struck by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.215 B09

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2015
Abate by
Jun 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) Maintenance Shop, on or about 3/31/2015: Employee operated a Delta 6" Bench Grinder with the abrasive wheel tongue guard was not adjusted to 1/4 of an inch, exposing employee to a struck by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 IV

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
May 22, 2015
Abate by
Jun 4, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a) Maintenance Shop, on or about 3/31/2015: Acetylene and Oxygen tanks were stored in a kart with regulators connected and not separated by a fire wall, employee was exposed to a fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.303 F02

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
May 22, 2015
Abate by
Jul 10, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) Maintenance Shop, on or about 3/31/2015: Challenge Electrical Distribution Panel was not label identifying to which equipment each circuit overcurrent device belongs, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.303 G01 I A

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
May 22, 2015
Abate by
Jul 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  a) Maintenance Shop, on or about 3/31/2015: Challenger Electrical Distribution Panel was blocked by an Ingersoll Rand 80 gallon air compressor, employees were exposed to a fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340524578.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.