Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EVANS GORDON FUNERAL HOME

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EVANS GORDON FUNERAL HOME in 736 CLINTON AVENUE, NEWARK, NJ 07108 (NAICS 812210). OSHA activity number 340524743.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Evans Gordon Funeral Home — free Get an email when a new federal OSHA severe-injury report for Evans Gordon Funeral Home is published. One employer, no account, unsubscribe in one click.
Site address
736 CLINTON AVENUE
City
NEWARK
State
NJ
ZIP
07108
Mailing
736 CLINTON AVENUE, NEWARK, NJ 07108
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812210
Employees
6
Ownership type
A

8 citations on file for this inspection.

1910.1030 C01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually:    a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.    The employer failed to perform an annual review of their Exposure Control Plan for the morticians that have reasonably anticipated exposure to blood or other potentially infectious material.    Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.1030 G02 II B

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.1030(g)(2)(ii)(B): The employer did not ensure that the training was provided to employees with occupational exposure at least annually:    a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.    The employer failed to provide annual bloodborne pathogens training for the morticians that have reasonably anticipated exposure to blood or other potentially infectious material.    Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.1048 D01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $1,600 · Current $960 Reduced

Hazardous substances 1290

29 CFR 1910.1048(d)(1)(i): Employees of a workplace covered by this standard were not monitored to determine their exposure to formaldehyde:    a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.    The employer failed to provide exposure monitoring for employees exposed to formaldehyde levels during embalming operations.  The products used were Jaundrol (37% formaldehyde), and Cavity King (30% formaldehyde) brand embalming fluids.        Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.1048 D02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 1290

29 CFR 1910.1048(d)(2)(i): A representative sampling strategy was not developed and sufficient formaldehyde exposures within each job classification for each work shift  were not measured to correctly characterize and not underestimate the exposure of any employee within each exposure group:  a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.  The employer did not identify employees who may be exposed to formaldehyde at or above the action level or short term exposure limit (STEL).  Employees performing embalming operations are exposed to formaldehyde which is contained in the Jaundrol (37% formaldehyde), and Cavity King (30% formaldehyde) brand embalming fluids.    Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1048 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $1,600 · Current $960 Reduced

Hazardous substances 1290

29 CFR 1910.1048(g)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii), (d)(3)(iii)(B)(1), and (d)(2)) and (f) through (m), which covers each employee required by 29 CFR 1910.1048 to use a respirator:    a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.    The employer failed to implement their written respiratory protection program for employees exposed to formaldehyde required to wear 3M brand half-face piece respirators with P100/OV cartridges during embalming operations.    Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.134 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 1290

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.  The employer failed to provide a medical evaluation for employees exposed to formaldehyde prior to requiring them to wear 3M brand half-face piece respirators with P100/OV cartridges during embalming operations.   Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 1290

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.  The employer failed to provide a fit test for employees exposed to formaldehyde prior to requiring them to wear 3M brand half-face piece respirators with P100/OV cartridges during embalming operations.  Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2015
Abate by
Aug 20, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 1290

29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a) Embalming and Preparation Room, Basement, Evans Gordon Funeral Home, 736 Clinton Avenue, Newark, NJ 07108.  The employer failed to provide training for employees exposed to formaldehyde prior to requiring them to wear 3M brand half-face piece respirators with P100/OV cartridges during embalming operations.  Condition observed on or about 4/8/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340524743.