WEST HARTFORD, CT —
OSHA Inspection: UNITED TOOL & DIE COMPANY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UNITED TOOL & DIE COMPANY, INC. in 1 CARNEY ROAD, WEST HARTFORD, CT 06110 (NAICS 336413). OSHA activity number 340524966.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED TOOL & DIE COMPANY, INC.
- Site address
- 1 CARNEY ROAD
- City
- WEST HARTFORD
- State
- CT
- ZIP
- 06110
- Mailing
- 1 CARNEY ROAD, WEST HARTFORD, CT 06110
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336413
- Employees
- 105
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 A05
- Issued
- Jun 4, 2015
- Abate by
- Sep 2, 2015
- Penalty
- Initial $3,060 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): Powered industrial truck(s) equipped with front-end attachments other than factory installed attachments require the user to request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: A. On or about April 9, 2015, Receiving Area: 1. CAT GP20K with standard 42 inch forks did not have the 96-inch fork attachments identified on the data plate. 2. CAT 50 GP25 with 45 inch forks did not have the 96-inch fork attachments identified on the data plate.
Recent events (2)
- — I (S) $1530
- — Z (S) $3060
1910.242 B
- Issued
- Jun 4, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $3,060 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: A. On or about April 9, 2015, Chop Saw Room: In the following locations, compressed air used for cleaning was not reduced to below 30 p.s.i.: 1. Chop Saw Room, at Haberle 77 saw. 2. Chop Saw Room, at the workbench. 3. Tool & Die Area, at Trak DPM5 bed mill #6.
Recent events (2)
- — I (S) $1530
- — Z (S) $3060
1910.303 B02
- Issued
- Jun 4, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $3,060 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A. On or about April 9, 2015, Chop Saw Room: A wall-mount listed 2-receptacle outlet box, labeled "Panel 12," was used to provide pendant power to a pedestal fan and belt sander near the work bench.
Recent events (2)
- — I (S) $1530
- — Z (S) $3060
1910.304 F01 IV
- Issued
- Jun 4, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $3,825 · Current $1,913 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: A. On or about April 9, 2015, in the following locations, overcurrent devices were not readily accessible: 1. Cutoff Room: 120/208V electrical panel powering shop equipment was not readily accessible, in that a green plastic container, cardboard waste barrel and cardboard box were located in front of it. 2. Tool & Die Area: 120/208V electrical Panel 9 was not readily accessible in that a blue recycle bin was located in front of it. 3. Tool & Die Area: 120/208V electrical Panel 7 was not readily accessible in that a welding cart had been placed in front of it. 4. Outside Polishing Room: An unlabeled 120/208V electrical panel was not readily accessible in that cardboard boxes of parts were stored in front of the panel.
Recent events (2)
- — I (S) $1912.5
- — Z (S) $3825
1910.305 G02 III
- Issued
- Jun 4, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $3,060 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: A. On or about April 9, 2015, Receiving Area: Insulation for the cord powering the lift on the Niagara squaring shear had been pulled from its fitting, exposing employees to the energized wires and electric shock hazards.
Recent events (2)
- — I (S) $1530
- — Z (S) $3060
1910.134 K06
- Issued
- Jun 4, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: A. On or about April 9, 2015, Establishment: The employer had not provided a copy of Appendix D to OSHA's respiratory protection standard, 29 CFR 1910.134, to employees using N95 filtering facepiece respirators on a voluntary basis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at United Tool & DIE Company, INC.
View United Tool & DIE Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336413)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340524966.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.