CAMILLUS, NY —
OSHA Inspection: BOYER'S CARPENTRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOYER'S CARPENTRY in MESA GRANDE TAQUERIA, TOWNSHIP 5, CAMILLUS, NY 13031 (NAICS 238350). OSHA activity number 340527282.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOYER'S CARPENTRY
- Site address
- MESA GRANDE TAQUERIA, TOWNSHIP 5
- City
- CAMILLUS
- State
- NY
- ZIP
- 13031
- Mailing
- 30 SECOND AVENUE, AUBURN, NY 13021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.300 B01
- Issued
- Apr 22, 2015
- Abate by
- May 2, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) East end of building, on or about 4-8-15: One employee was using a portable, hand-held electric angle grinder that was not equipped with a protective guard. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.304 F
- Issued
- Apr 22, 2015
- Abate by
- May 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) East end of building, on or about 4-8-15: One employee was ripping plywood on a table saw that was not equipped with a spreader. b) East end of building, on or about 4-8-15: One employee was ripping plywood on a table saw that was not equipped with non kick-back fingers or "dogs". c) East end of building, on or about 4-8-15: One employee was ripping plywood on a table saw that was not equipped a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.304 I01
- Issued
- Apr 22, 2015
- Abate by
- May 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) East end of building, on or about 4-8-15: One employee was ripping plywood on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Apr 22, 2015
- Abate by
- May 2, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) East end of building, on or about 4-8-15: One employee was operating power tools that were plugged into a relocatable power tap (RPT) that was not being used in accordance with the manufacturers recommendations or as listed and labeled. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.404 B01 II
- Issued
- Apr 22, 2015
- Abate by
- May 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) East end of building, on or about 4-8-15: One employee was operating various portable hand tools that were not protected by a ground fault circuit interrupter (GFCI). ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Apr 22, 2015
- Abate by
- May 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous: a) East end of building, on or about 4-8-15: One employee was operating various portable hand tools that did not have a continuous path to ground due to a missing ground pins. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238350)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340527282.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.