VICTOR, NY —
OSHA Inspection: INDOOR AIR TECHNOLOGIES
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of INDOOR AIR TECHNOLOGIES in 61 SCHOOL STREET, VICTOR, NY 14564 (NAICS 238160). OSHA activity number 340527571.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDOOR AIR TECHNOLOGIES
- Site address
- 61 SCHOOL STREET
- City
- VICTOR
- State
- NY
- ZIP
- 14564
- Mailing
- 33 WEST MAIN STREET, VICTOR, NY 14564
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B11
- Issued
- May 21, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $4,900 · Current $1,167 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) At the jobsite, on the roof, on or about 4/7/15: Two workers were stripping a shingle roof on a 6:12 pitch, with a ground to eave height of 14 feet 3 inches, without fall protection of any kind. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $1167
- — C (S) $4900
- — Z (S) $4900
1926.501 B10
- Issued
- May 21, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arr a) At the jobsite, on the upper roof, on or about 4/7/15: Two workers moved a tarp from the lower roof to the upper roof, a 4:12 pitch, with a ground to eave height of 16 feet, without fall protection of any kind. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- May 21, 2015
- Penalty
- Initial $3,500 · Current $833 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing being accessed: a) At the jobsite, on or about 4/7/15: Two workers accessed a 6:12 pitch roof with a ground to eave height of 14 feet 3 inches, with an extension ladder that did not extend at least 3 feet above the upper landing.
Recent events (3)
- — J (S) $833
- — C (S) $3500
- — Z (S) $3500
More inspections at Indoor AIR Technologies
View Indoor AIR Technologies's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340527571.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.