MIDDLETOWN, PA —
OSHA Inspection: DOLI CONSTRUCTION CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DOLI CONSTRUCTION CORPORATION in 400 BLOCK OF EAST MAIN STREET, MIDDLETOWN, PA 17057 (NAICS 237110). OSHA activity number 340528157.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DOLI CONSTRUCTION CORPORATION
- Site address
- 400 BLOCK OF EAST MAIN STREET
- City
- MIDDLETOWN
- State
- PA
- ZIP
- 17057
- Mailing
- 120 INDEPENDENCE LANE, CHALFONT, PA 18914
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- May 21, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $3,500 · Current $2,275 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: (a) Route 230/Main Street Infrastructure Improvement Project, Middletown, Pennsylvania - Employees used Efficiency Production single-cylinder rail hydraulic shoring for cave-in protection. The foreman and employees required training on this hydraulic shoring because neither the employees nor the foreman knew how to correctly install this hydraulic shoring, exposing the employees to a cave-in hazard, on or about April 9, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2275
- — Z (S) $3500
1926.652 C02 I
- Issued
- May 21, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $0 · Current $0
S777
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: (a) 400 Block of East Main Street, Middletown, Pennsylvania - Two employees worked at the bottom of a 6-foot deep trench, dug in Type B soil, to install a fitting on the new water line. For protection from cave-in in the area of the trench where the employees installed this fitting, the employees used one Efficiency Production single-cylinder rail (hydraulic shoring) with the cylinder installed one foot down from the top of the trench and at least 5 feet up from the bottom of the trench, which did not comply with the manufacturer's tabulated data for installation, exposing the employees to a cave-in hazard, on or about April 9, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 C02 III
- Issued
- May 21, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations were not in written form at the jobsite during construction of the protective system and thereafter until the protective system was no longer utilized: (a) Route 230/Main Street Infrastructure Improvement Project, Middletown, Pennsylvania - Employees used Efficiency Production, Inc. single-cylinder rail hydraulic shoring for cave-in protection. The employer did not have the manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations in written form at the jobsite during construction of the hydraulic shoring system and thereafter until no longer utilizing the hydraulic shoring system, exposing the employees to a cave-in hazard, on or about April 9, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Doli Construction Corporation
View Doli Construction Corporation's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340528157.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.